Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"docsPnmCmtsDsOfdmSymTrigGroupId",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"65535",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This attribute is used by the CMTS to be inserted in the PLC Trigger Message Block to identify a CM or a group of CMs expected to perform Symbol Capture measurements for the designated symbol. This value can only be changed while a test is not in progress. An attempt to set this value while the value of 'docsPnmCmtsDsOfdmSymMeasStatus' is 'busy' will return 'inconsistentValue'.\"",
"REFERENCE",
"\"DOCSIS 3.1 CCAP Operations Support System Interface Specification, CM-SP-CCAP-OSSIv3.1, PNM section.\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"docsPnmCmtsDsOfdmSymCapEntry",
"2",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
65535
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This attribute is used by the CMTS to be inserted in the PLC Trigger Message Block to identify a CM or a group of CMs expected to perform Symbol Capture measurements for the designated symbol. This value can only be changed while a test is not in progress. An attempt to set this value while the value of 'docsPnmCmtsDsOfdmSymMeasStatus' is 'busy' will return 'inconsistentValue'."
],
[
"REFERENCE",
"DOCSIS 3.1 CCAP Operations Support System Interface Specification, CM-SP-CCAP-OSSIv3.1, PNM section."
],
null,
null,
[
"DEFVAL",
0
]
]
}