Reference record for OID 1.3.6.1.4.1.4491.2.1.30.1.1.17.1.2

Parent
1.3.6.1.4.1.4491.2.1.30.1.1.17.1 (docsRphyRpdDevHostResStorEntry)
Node code
2
Node name
docsRphyRpdDevHostResStorType
Numeric OID
1.3.6.1.4.1.4491.2.1.30.1.1.17.1.2
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.30.1.1.17.1.2
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 30 1 1 17 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdDevMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdDevMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdDevMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdDevMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdDevMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdDevMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdDevMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdDevMibObjects(1) docsRphyRpdDevHostResStorTable(17) docsRphyRpdDevHostResStorEntry(1) docsRphyRpdDevHostResStorType(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/30/1/1/17/1/2
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/30/1/1/17/1/2
  • /ISO/3/6/1/4/1/4491/2/1/30/1/1/17/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdDevMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdDevMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdDevMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdDevMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdDevMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdDevMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdDevMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdDevMibObjects/docsRphyRpdDevHostResStorTable/docsRphyRpdDevHostResStorEntry/docsRphyRpdDevHostResStorType
  • Additional combinations skipped.

Descriptions

docsRphyRpdDevHostResStorType — CableLabs official current and historical MIBs

This attribute contains the type of storage represented by this object. The following storage types are supported: other: The storage type identifier used when no other defined type is appropriate ram: The storage type identifier used for RAM. virtualMemory: The storage type identifier used for virtual memory, temporary storage of swapped or paged memory. fixedDisk: The storage type identifier used for non-removable rigid rotating magnetic storage devices. removableDisk: The storage type identifier used for removable rigid rotating magnetic storage devices. floppyDisk: The storage type identifier used for non-rigid rotating magnetic storage devices. compactDisc: The storage type identifier used for read-only rotating optical storage devices. ramDisk: The storage type identifier used for a file system that is stored in RAM. flashMemory: The storage type identifier used for flash memory. networkDisk: The storage type identifier used for a networked file system.

docsRphyRpdDevHostResStorType — CableLabs official current and historical MIBs

The type of storage represented by this entry.

Source records

docsRphyRpdDevHostResStorType

Status in source: current.

Names: docsRphyRpdDevHostResStorType

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdDevHostResStorType",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "ram",
    "(",
    "2",
    ")",
    ",",
    "virtualMemory",
    "(",
    "3",
    ")",
    ",",
    "fixedDisk",
    "(",
    "4",
    ")",
    ",",
    "removableDisk",
    "(",
    "5",
    ")",
    ",",
    "floppyDisk",
    "(",
    "6",
    ")",
    ",",
    "compactDisc",
    "(",
    "7",
    ")",
    ",",
    "ramDisk",
    "(",
    "8",
    ")",
    ",",
    "flashMemory",
    "(",
    "9",
    ")",
    ",",
    "networkDisk",
    "(",
    "10",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute contains the type of storage represented by this object. The following storage types are supported: other: The storage type identifier used when no other defined type is appropriate ram: The storage type identifier used for RAM. virtualMemory: The storage type identifier used for virtual memory, temporary storage of swapped or paged memory. fixedDisk: The storage type identifier used for non-removable rigid rotating magnetic storage devices. removableDisk: The storage type identifier used for removable rigid rotating magnetic storage devices. floppyDisk: The storage type identifier used for non-rigid rotating magnetic storage devices. compactDisc: The storage type identifier used for read-only rotating optical storage devices. ramDisk: The storage type identifier used for a file system that is stored in RAM. flashMemory: The storage type identifier used for flash memory. networkDisk: The storage type identifier used for a networked file system.\"",
    "REFERENCE",
    "\"Information Model Mapping: CM-SP-R-OSSI HostResourcesStorage::Type\"",
    "::=",
    "{",
    "docsRphyRpdDevHostResStorEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "ram",
            2
          ],
          [
            "virtualMemory",
            3
          ],
          [
            "fixedDisk",
            4
          ],
          [
            "removableDisk",
            5
          ],
          [
            "floppyDisk",
            6
          ],
          [
            "compactDisc",
            7
          ],
          [
            "ramDisk",
            8
          ],
          [
            "flashMemory",
            9
          ],
          [
            "networkDisk",
            10
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute contains the type of storage represented by this object. The following storage types are supported: other: The storage type identifier used when no other defined type is appropriate ram: The storage type identifier used for RAM. virtualMemory: The storage type identifier used for virtual memory, temporary storage of swapped or paged memory. fixedDisk: The storage type identifier used for non-removable rigid rotating magnetic storage devices. removableDisk: The storage type identifier used for removable rigid rotating magnetic storage devices. floppyDisk: The storage type identifier used for non-rigid rotating magnetic storage devices. compactDisc: The storage type identifier used for read-only rotating optical storage devices. ramDisk: The storage type identifier used for a file system that is stored in RAM. flashMemory: The storage type identifier used for flash memory. networkDisk: The storage type identifier used for a networked file system."
    ],
    [
      "REFERENCE",
      "Information Model Mapping: CM-SP-R-OSSI HostResourcesStorage::Type"
    ],
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-01-20.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             HostResourcesStorage::Type"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-01-20.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.394938+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-03-31.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             HostResourcesStorage::Type"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-03-31.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.424309+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-06-30.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             HostResourcesStorage::Type"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.542970+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-12-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             HostResourcesStorage::Type"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-12-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.089920+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2023-10-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             HostResourcesStorage::Type"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['InterfaceIndex', 'TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download DOCS-RPHY-MIB-2023-10-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.579257+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2024-01-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             HostResourcesStorage::Type"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2024-01-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.575041+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2025-01-23.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             HostResourcesStorage::Type"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2025-01-23.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.705674+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB.mib

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             HostResourcesStorage::Type"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB.mib
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:47:25.372984+00:00.

docsRphyRpdDevHostResStorType

Status in source: current.

Names: docsRphyRpdDevHostResStorType

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdDevHostResStorType",
    "OBJECT-TYPE",
    "SYNTAX",
    "AutonomousType",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The type of storage represented by this entry.\"",
    "::=",
    "{",
    "docsRphyRpdDevHostResStorEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "AutonomousType"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The type of storage represented by this entry."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2017-08-10.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
           SYNTAX  AutonomousType
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
    	    "The type of storage represented by this entry."
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2017-08-10.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.646573+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2017-11-16.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
           SYNTAX  AutonomousType
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
    	    "The type of storage represented by this entry."
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2017-11-16.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.785025+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-04-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
           SYNTAX  AutonomousType
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
    	    "The type of storage represented by this entry."
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-04-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.813434+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-07-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
           SYNTAX  AutonomousType
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
    	    "The type of storage represented by this entry."
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-07-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:54.177098+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-10-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
           SYNTAX  AutonomousType
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
    	    "The type of storage represented by this entry."
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-10-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:54.895530+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-01-24.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
           SYNTAX  AutonomousType
           MAX-ACCESS  read-only
           STATUS  current
           DESCRIPTION
    	    "The type of storage represented by this entry."
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-01-24.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.074775+00:00.

docsRphyRpdDevHostResStorType

Status in source: current.

Names: docsRphyRpdDevHostResStorType

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdDevHostResStorType",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "ram",
    "(",
    "2",
    ")",
    ",",
    "virtualMemory",
    "(",
    "3",
    ")",
    ",",
    "fixedDisk",
    "(",
    "4",
    ")",
    ",",
    "removableDisk",
    "(",
    "5",
    ")",
    ",",
    "floppyDisk",
    "(",
    "6",
    ")",
    ",",
    "compactDisc",
    "(",
    "7",
    ")",
    ",",
    "ramDisk",
    "(",
    "8",
    ")",
    ",",
    "flashMemory",
    "(",
    "9",
    ")",
    ",",
    "networkDisk",
    "(",
    "10",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute contains the type of storage represented by this object. The following storage types are supported: other: The storage type identifier used when no other defined type is appropriate ram: The storage type identifier used for RAM. virtualMemory: The storage type identifier used for virtual memory, temporary storage of swapped or paged memory. fixedDisk: The storage type identifier used for non-removable rigid rotating magnetic storage devices. removableDisk: The storage type identifier used for removable rigid rotating magnetic storage devices. floppyDisk: The storage type identifier used for non-rigid rotating magnetic storage devices. compactDisc: The storage type identifier used for read-only rotating optical storage devices. ramDisk: The storage type identifier used for a file system that is stored in RAM. flashMemory: The storage type identifier used for flash memory. networkDisk: The storage type identifier used for a networked file system.\"",
    "REFERENCE",
    "\"[RFC 2790] HOST-RESOURCES-TYPES MIB\"",
    "::=",
    "{",
    "docsRphyRpdDevHostResStorEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "ram",
            2
          ],
          [
            "virtualMemory",
            3
          ],
          [
            "fixedDisk",
            4
          ],
          [
            "removableDisk",
            5
          ],
          [
            "floppyDisk",
            6
          ],
          [
            "compactDisc",
            7
          ],
          [
            "ramDisk",
            8
          ],
          [
            "flashMemory",
            9
          ],
          [
            "networkDisk",
            10
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute contains the type of storage represented by this object. The following storage types are supported: other: The storage type identifier used when no other defined type is appropriate ram: The storage type identifier used for RAM. virtualMemory: The storage type identifier used for virtual memory, temporary storage of swapped or paged memory. fixedDisk: The storage type identifier used for non-removable rigid rotating magnetic storage devices. removableDisk: The storage type identifier used for removable rigid rotating magnetic storage devices. floppyDisk: The storage type identifier used for non-rigid rotating magnetic storage devices. compactDisc: The storage type identifier used for read-only rotating optical storage devices. ramDisk: The storage type identifier used for a file system that is stored in RAM. flashMemory: The storage type identifier used for flash memory. networkDisk: The storage type identifier used for a networked file system."
    ],
    [
      "REFERENCE",
      "[RFC 2790] HOST-RESOURCES-TYPES MIB"
    ],
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-06-13.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE "[RFC 2790] HOST-RESOURCES-TYPES MIB"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-06-13.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.180890+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-09-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE "[RFC 2790] HOST-RESOURCES-TYPES MIB"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-09-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.289076+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-01-09.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE "[RFC 2790] HOST-RESOURCES-TYPES MIB"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-01-09.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.938082+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-05-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE "[RFC 2790] HOST-RESOURCES-TYPES MIB"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-05-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.205690+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-10-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE "[RFC 2790] HOST-RESOURCES-TYPES MIB"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-10-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.354948+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-03-11.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE "[RFC 2790] HOST-RESOURCES-TYPES MIB"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-03-11.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.429401+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-10-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdDevHostResStorType OBJECT-TYPE
        SYNTAX       INTEGER {
                              other(1),
                              ram(2),
                              virtualMemory(3),
                              fixedDisk(4),
                              removableDisk(5),
                              floppyDisk(6),
                              compactDisc(7),
                              ramDisk(8),
                              flashMemory(9),
                              networkDisk(10)
                            }
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute contains the type of storage represented
             by this object. The following storage types are supported:
    
             other: The storage type identifier used when no other 
             defined type is appropriate
    
             ram: The storage type identifier used for RAM.
    
             virtualMemory: The storage type identifier used for virtual memory, 
             temporary storage of swapped or paged memory.
    
             fixedDisk: The storage type identifier used for non-removable 
             rigid rotating magnetic storage devices.
    
             removableDisk: The storage type identifier used for removable 
             rigid rotating magnetic storage devices.
    
             floppyDisk: The storage type identifier used for non-rigid 
             rotating magnetic storage devices.
    
             compactDisc: The storage type identifier used for read-only
             rotating optical storage devices.
    
             ramDisk: The storage type identifier used for a file system 
             that is stored in RAM.
    
             flashMemory: The storage type identifier used for flash memory.
    
             networkDisk: The storage type identifier used for a networked
             file system."
        REFERENCE "[RFC 2790] HOST-RESOURCES-TYPES MIB"
           ::= { docsRphyRpdDevHostResStorEntry 2 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdDevHostResStorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.003028+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Siblings (6)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.30.1.1.17.1.1 docsRphyRpdDevHostResStorIndex00
1.3.6.1.4.1.4491.2.1.30.1.1.17.1.3 docsRphyRpdDevHostResStorAllocationUnits00
1.3.6.1.4.1.4491.2.1.30.1.1.17.1.4 docsRphyRpdDevHostResStorAllocationFailures00
1.3.6.1.4.1.4491.2.1.30.1.1.17.1.5 docsRphyRpdDevHostResStorSize00
1.3.6.1.4.1.4491.2.1.30.1.1.17.1.6 docsRphyRpdDevHostResStorUsed00
1.3.6.1.4.1.4491.2.1.30.1.1.17.1.7 docsRphyRpdDevHostResStorDescr00