Reference record for OID 1.3.6.1.4.1.4491.2.1.30.1.2.1.1.6

Parent
1.3.6.1.4.1.4491.2.1.30.1.2.1.1 (docsRphyRpdPhysEntityEntry, docsRphyRpdIfPhysEntityEntry)
Node code
6
Node names
  • docsRphyRpdPhysEntityParentRelPos
  • docsRphyRpdIfPhysEntityParentRelPos
Numeric OID
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.6
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.30.1.2.1.1.6
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 30 1 2 1 1 6}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdPhysEntityTable(1) docsRphyRpdPhysEntityEntry(1) docsRphyRpdPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdPhysEntityTable(1) docsRphyRpdPhysEntityEntry(1) docsRphyRpdIfPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdPhysEntityTable(1) docsRphyRpdIfPhysEntityEntry(1) docsRphyRpdPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdPhysEntityTable(1) docsRphyRpdIfPhysEntityEntry(1) docsRphyRpdIfPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfPhysEntityTable(1) docsRphyRpdPhysEntityEntry(1) docsRphyRpdPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfPhysEntityTable(1) docsRphyRpdPhysEntityEntry(1) docsRphyRpdIfPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfPhysEntityTable(1) docsRphyRpdIfPhysEntityEntry(1) docsRphyRpdPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfPhysEntityTable(1) docsRphyRpdIfPhysEntityEntry(1) docsRphyRpdIfPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdPhysEntityTable(1) docsRphyRpdPhysEntityEntry(1) docsRphyRpdPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdPhysEntityTable(1) docsRphyRpdPhysEntityEntry(1) docsRphyRpdIfPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdPhysEntityTable(1) docsRphyRpdIfPhysEntityEntry(1) docsRphyRpdPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdPhysEntityTable(1) docsRphyRpdIfPhysEntityEntry(1) docsRphyRpdIfPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfPhysEntityTable(1) docsRphyRpdPhysEntityEntry(1) docsRphyRpdPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfPhysEntityTable(1) docsRphyRpdPhysEntityEntry(1) docsRphyRpdIfPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfPhysEntityTable(1) docsRphyRpdIfPhysEntityEntry(1) docsRphyRpdPhysEntityParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfPhysEntityTable(1) docsRphyRpdIfPhysEntityEntry(1) docsRphyRpdIfPhysEntityParentRelPos(6)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/30/1/2/1/1/6
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/30/1/2/1/1/6
  • /ISO/3/6/1/4/1/4491/2/1/30/1/2/1/1/6
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdPhysEntityTable/docsRphyRpdPhysEntityEntry/docsRphyRpdPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdPhysEntityTable/docsRphyRpdPhysEntityEntry/docsRphyRpdIfPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdPhysEntityTable/docsRphyRpdIfPhysEntityEntry/docsRphyRpdPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdPhysEntityTable/docsRphyRpdIfPhysEntityEntry/docsRphyRpdIfPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfPhysEntityTable/docsRphyRpdPhysEntityEntry/docsRphyRpdPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfPhysEntityTable/docsRphyRpdPhysEntityEntry/docsRphyRpdIfPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfPhysEntityTable/docsRphyRpdIfPhysEntityEntry/docsRphyRpdPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfPhysEntityTable/docsRphyRpdIfPhysEntityEntry/docsRphyRpdIfPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdPhysEntityTable/docsRphyRpdPhysEntityEntry/docsRphyRpdPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdPhysEntityTable/docsRphyRpdPhysEntityEntry/docsRphyRpdIfPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdPhysEntityTable/docsRphyRpdIfPhysEntityEntry/docsRphyRpdPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdPhysEntityTable/docsRphyRpdIfPhysEntityEntry/docsRphyRpdIfPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfPhysEntityTable/docsRphyRpdPhysEntityEntry/docsRphyRpdPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfPhysEntityTable/docsRphyRpdPhysEntityEntry/docsRphyRpdIfPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfPhysEntityTable/docsRphyRpdIfPhysEntityEntry/docsRphyRpdPhysEntityParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfPhysEntityTable/docsRphyRpdIfPhysEntityEntry/docsRphyRpdIfPhysEntityParentRelPos
  • Additional combinations skipped.

Descriptions

docsRphyRpdIfPhysEntityParentRelPos — CableLabs official current and historical MIBs

An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as docsRphyRpdIfPhysEntityEntries that share the same instance values of each of the docsRphyRpdIfPhysEntityContainedIn and docsRphyRpdIfPhysEntityClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', docsRphyRpdIfPhysEntityParentRelPos should have the value '3'. Note that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3 should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an docsRphyRpdIfPhysEntityParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage.

docsRphyRpdPhysEntityParentRelPos — CableLabs official current and historical MIBs

An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as docsRphyRpdPhysEntityEntries that share the same instance values of each of the docsRphyRpdPhysEntityContainedIn and docsRphyRpdPhysEntityClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the docsRphyRpdPhysEntityContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', docsRphyRpdPhysEntityParentRelPos should have the value '3'. Note that the docsRphyRpdPhysEntityEntry for the module plugged in slot 3 should have an docsRphyRpdPhysEntityParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of docsRphyRpdPhysEntityContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an docsRphyRpdPhysEntityParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage.

Source records

docsRphyRpdIfPhysEntityParentRelPos

Status in source: current.

Names: docsRphyRpdIfPhysEntityParentRelPos

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfPhysEntityParentRelPos",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "1",
    ".",
    ".",
    "2147483647",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as docsRphyRpdIfPhysEntityEntries that share the same instance values of each of the docsRphyRpdIfPhysEntityContainedIn and docsRphyRpdIfPhysEntityClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', docsRphyRpdIfPhysEntityParentRelPos should have the value '3'. Note that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3 should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an docsRphyRpdIfPhysEntityParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage.\"",
    "::=",
    "{",
    "docsRphyRpdIfPhysEntityEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -1,
            2147483647
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as docsRphyRpdIfPhysEntityEntries that share the same instance values of each of the docsRphyRpdIfPhysEntityContainedIn and docsRphyRpdIfPhysEntityClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', docsRphyRpdIfPhysEntityParentRelPos should have the value '3'. Note that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3 should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an docsRphyRpdIfPhysEntityParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2016-09-29.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2016-09-29.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:52.609764+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2016-12-15.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2016-12-15.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:52.713300+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2017-04-13.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2017-04-13.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.164526+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2017-08-10.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2017-08-10.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.646573+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2017-11-16.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2017-11-16.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.785025+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-04-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-04-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.813434+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-07-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-07-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:54.177098+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-10-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-10-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:54.895530+00:00.

docsRphyRpdPhysEntityParentRelPos

Status in source: current.

Names: docsRphyRpdPhysEntityParentRelPos

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdPhysEntityParentRelPos",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "1",
    ".",
    ".",
    "2147483647",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as docsRphyRpdPhysEntityEntries that share the same instance values of each of the docsRphyRpdPhysEntityContainedIn and docsRphyRpdPhysEntityClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the docsRphyRpdPhysEntityContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', docsRphyRpdPhysEntityParentRelPos should have the value '3'. Note that the docsRphyRpdPhysEntityEntry for the module plugged in slot 3 should have an docsRphyRpdPhysEntityParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of docsRphyRpdPhysEntityContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an docsRphyRpdPhysEntityParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage.\"",
    "::=",
    "{",
    "docsRphyRpdPhysEntityEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -1,
            2147483647
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as docsRphyRpdPhysEntityEntries that share the same instance values of each of the docsRphyRpdPhysEntityContainedIn and docsRphyRpdPhysEntityClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the docsRphyRpdPhysEntityContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', docsRphyRpdPhysEntityParentRelPos should have the value '3'. Note that the docsRphyRpdPhysEntityEntry for the module plugged in slot 3 should have an docsRphyRpdPhysEntityParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of docsRphyRpdPhysEntityContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an docsRphyRpdPhysEntityParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2016-04-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (-1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdPhysEntityContainedIn
                and docsRphyRpdPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'IpAddressPrefixOriginTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'DisplayString'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2016-04-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:52.597555+00:00.

docsRphyRpdIfPhysEntityParentRelPos

Status in source: current.

Names: docsRphyRpdIfPhysEntityParentRelPos

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfPhysEntityParentRelPos",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "1",
    ".",
    ".",
    "2147483647",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as docsRphyRpdIfPhysEntityEntries that share the same instance values of each of the docsRphyRpdIfPhysEntityContainedIn and docsRphyRpdIfPhysEntityClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', docsRphyRpdIfPhysEntityParentRelPos should have the value '3'. Note that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3 should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an docsRphyRpdIfPhysEntityParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage.\"",
    "::=",
    "{",
    "docsRphyRpdIfPhysEntityEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            1,
            2147483647
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as docsRphyRpdIfPhysEntityEntries that share the same instance values of each of the docsRphyRpdIfPhysEntityContainedIn and docsRphyRpdIfPhysEntityClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each sibling entry). If possible, this value should match any external labeling of the physical component. For example, for a container (e.g., card slot) labeled as 'slot #3', docsRphyRpdIfPhysEntityParentRelPos should have the value '3'. Note that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3 should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is returned. Otherwise, a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with an docsRphyRpdIfPhysEntityParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-01-24.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "An indication of the relative position of this 'child'
                component among all its 'sibling' components.  Sibling
                components are defined as docsRphyRpdIfPhysEntityEntries that share the
                same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
                and docsRphyRpdIfPhysEntityClass objects.
    
                An NMS can use this object to identify the relative ordering
                for all sibling components of a particular parent
                (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
                sibling entry).
    
                If possible, this value should match any external labeling
                of the physical component.  For example, for a container
                (e.g., card slot) labeled as 'slot #3',
                docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
                that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
                should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
                If the physical position of this component does not match
                any external numbering or clearly visible ordering, then
                user documentation or other external reference material
                should be used to determine the parent-relative position.
                If this is not possible, then the agent should assign a
                consistent (but possibly arbitrary) ordering to a given set
                of 'sibling' components, perhaps based on internal
                representation of the components.
    
                If the agent cannot determine the parent-relative position
                for some reason, or if the associated value of
                docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
                returned.  Otherwise, a non-negative integer is returned,
                indicating the parent-relative position of this physical
                entity.
    
                Parent-relative ordering normally starts from '1' and
                continues to 'N', where 'N' represents the highest
                positioned child entity.  However, if the physical entities
                (e.g., slots) are labeled from a starting position of zero,
                then the first sibling should be associated with an
                docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
                ordering may be sparse or dense, depending on agent
                implementation.
    
                The actual values returned are not globally meaningful, as
                each 'parent' component may use different numbering
                algorithms.  The ordering is only meaningful among siblings
                of the same parent component.
    
                The agent should retain parent-relative position values
                across reboots, either through algorithmic assignment or use
                of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-01-24.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.074775+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-06-13.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-06-13.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.180890+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-09-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-09-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.289076+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-01-09.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-01-09.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.938082+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-05-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-05-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.205690+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-10-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-10-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.354948+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-03-11.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-03-11.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.429401+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-10-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.003028+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-01-20.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-01-20.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.394938+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-03-31.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-03-31.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.424309+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-06-30.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.542970+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-12-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-12-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.089920+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2023-10-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['InterfaceIndex', 'TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download DOCS-RPHY-MIB-2023-10-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.579257+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2024-01-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2024-01-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.575041+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2025-01-23.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2025-01-23.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.705674+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB.mib

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntityParentRelPos OBJECT-TYPE
        SYNTAX      Integer32 (1..2147483647)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "An indication of the relative position of this 'child'
             component among all its 'sibling' components.  Sibling
             components are defined as docsRphyRpdIfPhysEntityEntries that share the
             same instance values of each of the docsRphyRpdIfPhysEntityContainedIn
             and docsRphyRpdIfPhysEntityClass objects.
    
             An NMS can use this object to identify the relative ordering
             for all sibling components of a particular parent
             (identified by the docsRphyRpdIfPhysEntityContainedIn instance in each
             sibling entry).
    
             If possible, this value should match any external labeling
             of the physical component.  For example, for a container
             (e.g., card slot) labeled as 'slot #3',
             docsRphyRpdIfPhysEntityParentRelPos should have the value '3'.  Note
             that the docsRphyRpdIfPhysEntityEntry for the module plugged in slot 3
             should have an docsRphyRpdIfPhysEntityParentRelPos value of '1'.
    
             If the physical position of this component does not match
             any external numbering or clearly visible ordering, then
             user documentation or other external reference material
             should be used to determine the parent-relative position.
             If this is not possible, then the agent should assign a
             consistent (but possibly arbitrary) ordering to a given set
             of 'sibling' components, perhaps based on internal
             representation of the components.
    
             If the agent cannot determine the parent-relative position
             for some reason, or if the associated value of
             docsRphyRpdIfPhysEntityContainedIn is '0', then the value '-1' is
             returned.  Otherwise, a non-negative integer is returned,
             indicating the parent-relative position of this physical
             entity.
    
             Parent-relative ordering normally starts from '1' and
             continues to 'N', where 'N' represents the highest
             positioned child entity.  However, if the physical entities
             (e.g., slots) are labeled from a starting position of zero,
             then the first sibling should be associated with an
             docsRphyRpdIfPhysEntityParentRelPos value of '0'.  Note that this
             ordering may be sparse or dense, depending on agent
             implementation.
    
             The actual values returned are not globally meaningful, as
             each 'parent' component may use different numbering
             algorithms.  The ordering is only meaningful among siblings
             of the same parent component.
    
             The agent should retain parent-relative position values
             across reboots, either through algorithmic assignment or use
             of non-volatile storage."
        ::= { docsRphyRpdIfPhysEntityEntry 6 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB.mib
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntityParentRelPos.
    Source version and references

    Downloaded: 2026-10-26T22:47:25.372984+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Siblings (19)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.1 docsRphyRpdPhysEntityIndex, docsRphyRpdIfPhysEntityIndex00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.2 docsRphyRpdPhysEntityDescr, docsRphyRpdIfPhysEntityDescr00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.3 docsRphyRpdPhysEntityVendorType, docsRphyRpdIfPhysEntityVendorType00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.4 docsRphyRpdPhysEntityContainedIn, docsRphyRpdIfPhysEntityContainedIn00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.5 docsRphyRpdPhysEntityClass, docsRphyRpdIfPhysEntityClass00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.7 docsRphyRpdPhysEntityName, docsRphyRpdIfPhysEntityName00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.8 docsRphyRpdPhysEntityHardwareRev, docsRphyRpdIfPhysEntityHardwareRev00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.9 docsRphyRpdPhysEntityFirmwareRev, docsRphyRpdIfPhysEntityFirmwareRev00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.10 docsRphyRpdPhysEntitySoftwareRev, docsRphyRpdIfPhysEntitySoftwareRev00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.11 docsRphyRpdPhysEntitySerialNum, docsRphyRpdIfPhysEntitySerialNum00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.12 docsRphyRpdPhysEntityMfgName, docsRphyRpdIfPhysEntityMfgName00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.13 docsRphyRpdPhysEntityModelName, docsRphyRpdIfPhysEntityModelName00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.14 docsRphyRpdPhysEntityAlias, docsRphyRpdIfPhysEntityAlias00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.15 docsRphyRpdPhysEntityAssetID, docsRphyRpdIfPhysEntityAssetID00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.16 docsRphyRpdPhysEntityIsFRU, docsRphyRpdIfPhysEntityIsFRU00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.17 docsRphyRpdPhysEntityMfgDate, docsRphyRpdIfPhysEntityMfgDate00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.18 docsRphyRpdPhysEntityUris, docsRphyRpdIfPhysEntityUris00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.19 docsRphyRpdPhysEntityUUID, docsRphyRpdIfPhysEntityUUID00
1.3.6.1.4.1.4491.2.1.30.1.2.1.1.20 docsRphyRpdPhysEntityIfIndex, docsRphyRpdIfPhysEntityCoreIfIndex00