Reference record for OID 1.3.6.1.4.1.4491.2.1.30.1.2.2.1.3

Parent
1.3.6.1.4.1.4491.2.1.30.1.2.2.1 (docsRphyRpdPhysEntSensorEntry, docsRphyRpdIfPhysEntSensorEntry)
Node code
3
Node names
  • docsRphyRpdPhysEntSensorPrecision
  • docsRphyRpdIfPhysEntSensorPrecision
Numeric OID
1.3.6.1.4.1.4491.2.1.30.1.2.2.1.3
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.30.1.2.2.1.3
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 30 1 2 2 1 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdPhysEntSensorTable(2) docsRphyRpdPhysEntSensorEntry(1) docsRphyRpdPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdPhysEntSensorTable(2) docsRphyRpdPhysEntSensorEntry(1) docsRphyRpdIfPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdPhysEntSensorTable(2) docsRphyRpdIfPhysEntSensorEntry(1) docsRphyRpdPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdPhysEntSensorTable(2) docsRphyRpdIfPhysEntSensorEntry(1) docsRphyRpdIfPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfPhysEntSensorTable(2) docsRphyRpdPhysEntSensorEntry(1) docsRphyRpdPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfPhysEntSensorTable(2) docsRphyRpdPhysEntSensorEntry(1) docsRphyRpdIfPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfPhysEntSensorTable(2) docsRphyRpdIfPhysEntSensorEntry(1) docsRphyRpdPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfPhysEntSensorTable(2) docsRphyRpdIfPhysEntSensorEntry(1) docsRphyRpdIfPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdPhysEntSensorTable(2) docsRphyRpdPhysEntSensorEntry(1) docsRphyRpdPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdPhysEntSensorTable(2) docsRphyRpdPhysEntSensorEntry(1) docsRphyRpdIfPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdPhysEntSensorTable(2) docsRphyRpdIfPhysEntSensorEntry(1) docsRphyRpdPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdPhysEntSensorTable(2) docsRphyRpdIfPhysEntSensorEntry(1) docsRphyRpdIfPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfPhysEntSensorTable(2) docsRphyRpdPhysEntSensorEntry(1) docsRphyRpdPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfPhysEntSensorTable(2) docsRphyRpdPhysEntSensorEntry(1) docsRphyRpdIfPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfPhysEntSensorTable(2) docsRphyRpdIfPhysEntSensorEntry(1) docsRphyRpdPhysEntSensorPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfPhysEntSensorTable(2) docsRphyRpdIfPhysEntSensorEntry(1) docsRphyRpdIfPhysEntSensorPrecision(3)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/30/1/2/2/1/3
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/30/1/2/2/1/3
  • /ISO/3/6/1/4/1/4491/2/1/30/1/2/2/1/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdPhysEntSensorTable/docsRphyRpdPhysEntSensorEntry/docsRphyRpdPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdPhysEntSensorTable/docsRphyRpdPhysEntSensorEntry/docsRphyRpdIfPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdPhysEntSensorTable/docsRphyRpdIfPhysEntSensorEntry/docsRphyRpdPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdPhysEntSensorTable/docsRphyRpdIfPhysEntSensorEntry/docsRphyRpdIfPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfPhysEntSensorTable/docsRphyRpdPhysEntSensorEntry/docsRphyRpdPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfPhysEntSensorTable/docsRphyRpdPhysEntSensorEntry/docsRphyRpdIfPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfPhysEntSensorTable/docsRphyRpdIfPhysEntSensorEntry/docsRphyRpdPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfPhysEntSensorTable/docsRphyRpdIfPhysEntSensorEntry/docsRphyRpdIfPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdPhysEntSensorTable/docsRphyRpdPhysEntSensorEntry/docsRphyRpdPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdPhysEntSensorTable/docsRphyRpdPhysEntSensorEntry/docsRphyRpdIfPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdPhysEntSensorTable/docsRphyRpdIfPhysEntSensorEntry/docsRphyRpdPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdPhysEntSensorTable/docsRphyRpdIfPhysEntSensorEntry/docsRphyRpdIfPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfPhysEntSensorTable/docsRphyRpdPhysEntSensorEntry/docsRphyRpdPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfPhysEntSensorTable/docsRphyRpdPhysEntSensorEntry/docsRphyRpdIfPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfPhysEntSensorTable/docsRphyRpdIfPhysEntSensorEntry/docsRphyRpdPhysEntSensorPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfPhysEntSensorTable/docsRphyRpdIfPhysEntSensorEntry/docsRphyRpdIfPhysEntSensorPrecision
  • Additional combinations skipped.

Descriptions

docsRphyRpdIfPhysEntSensorPrecision — CableLabs official current and historical MIBs

This attribute reports the number of decimal places of precision in fixed-point sensor values returned by the associated Value attribute. This attribute should be set to '0' when the associated SensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.

docsRphyRpdPhysEntSensorPrecision — CableLabs official current and historical MIBs

The number of decimal places of precision in fixed-point sensor values returned by the associated docsRphyRpdEntPhySensorValue object. This object SHOULD be set to '0' when the associated docsRphyRpdEntPhySensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'. This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation.

Source records

docsRphyRpdIfPhysEntSensorPrecision

Status in source: current.

Names: docsRphyRpdIfPhysEntSensorPrecision

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfPhysEntSensorPrecision",
    "OBJECT-TYPE",
    "SYNTAX",
    "EntitySensorPrecision",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports the number of decimal places of precision in fixed-point sensor values returned by the associated Value attribute. This attribute should be set to '0' when the associated SensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.\"",
    "::=",
    "{",
    "docsRphyRpdIfPhysEntSensorEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "EntitySensorPrecision"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports the number of decimal places of precision in fixed-point sensor values returned by the associated Value attribute. This attribute should be set to '0' when the associated SensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2016-09-29.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2016-09-29.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:52.609764+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2016-12-15.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2016-12-15.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:52.713300+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2017-04-13.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2017-04-13.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.164526+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2017-08-10.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2017-08-10.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.646573+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2017-11-16.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2017-11-16.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.785025+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-04-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-04-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:53.813434+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-07-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-07-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:54.177098+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2018-10-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2018-10-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:54.895530+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-01-24.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "This attribute reports the number of decimal places of 
                 precision in fixed-point sensor values returned by the 
                 associated Value attribute.
                 This attribute should be set to '0' when the associated 
                 SensorType value is not a fixed-point type: e.g., 
                 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-01-24.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.074775+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-06-13.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-06-13.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.180890+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-09-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-09-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.289076+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-01-09.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-01-09.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.938082+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-05-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-05-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.205690+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-10-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-10-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.354948+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-03-11.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-03-11.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.429401+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-10-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.003028+00:00.

docsRphyRpdPhysEntSensorPrecision

Status in source: current.

Names: docsRphyRpdPhysEntSensorPrecision

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdPhysEntSensorPrecision",
    "OBJECT-TYPE",
    "SYNTAX",
    "EntitySensorPrecision",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The number of decimal places of precision in fixed-point sensor values returned by the associated docsRphyRpdEntPhySensorValue object. This object SHOULD be set to '0' when the associated docsRphyRpdEntPhySensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'. This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation.\"",
    "::=",
    "{",
    "docsRphyRpdPhysEntSensorEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "EntitySensorPrecision"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The number of decimal places of precision in fixed-point sensor values returned by the associated docsRphyRpdEntPhySensorValue object. This object SHOULD be set to '0' when the associated docsRphyRpdEntPhySensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'. This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2016-04-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
                "The number of decimal places of precision in fixed-point
                sensor values returned by the associated docsRphyRpdEntPhySensorValue
                object.
    
                This object SHOULD be set to '0' when the associated
                docsRphyRpdEntPhySensorType value is not a fixed-point type: e.g.,
                'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
    
                This object SHOULD be set by the agent during entry
                creation, and the value SHOULD NOT change during operation."
        ::= { docsRphyRpdPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'IpAddressPrefixOriginTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'DisplayString'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2016-04-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:52.597555+00:00.

docsRphyRpdIfPhysEntSensorPrecision

Status in source: current.

Names: docsRphyRpdIfPhysEntSensorPrecision

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfPhysEntSensorPrecision",
    "OBJECT-TYPE",
    "SYNTAX",
    "EntitySensorPrecision",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports the number of decimal places of precision in fixed-point sensor values returned by the associated Value attribute. This attribute should be set to '0' when the associated SensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.\"",
    "REFERENCE",
    "\"Information Model Mapping: CM-SP-R-OSSI Sensor::Precision\"",
    "::=",
    "{",
    "docsRphyRpdIfPhysEntSensorEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "EntitySensorPrecision"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports the number of decimal places of precision in fixed-point sensor values returned by the associated Value attribute. This attribute should be set to '0' when the associated SensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
    ],
    [
      "REFERENCE",
      "Information Model Mapping: CM-SP-R-OSSI Sensor::Precision"
    ],
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-01-20.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             Sensor::Precision"
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-01-20.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.394938+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-03-31.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             Sensor::Precision"
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-03-31.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.424309+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-06-30.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             Sensor::Precision"
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.542970+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-12-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             Sensor::Precision"
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-12-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.089920+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2023-10-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             Sensor::Precision"
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['InterfaceIndex', 'TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download DOCS-RPHY-MIB-2023-10-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.579257+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2024-01-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             Sensor::Precision"
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2024-01-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.575041+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2025-01-23.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             Sensor::Precision"
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2025-01-23.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.705674+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB.mib

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfPhysEntSensorPrecision OBJECT-TYPE
        SYNTAX        EntitySensorPrecision
        MAX-ACCESS    read-only
        STATUS        current
        DESCRIPTION
            "This attribute reports the number of decimal places of 
             precision in fixed-point sensor values returned by the 
             associated Value attribute.
             This attribute should be set to '0' when the associated 
             SensorType value is not a fixed-point type: e.g., 
             'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             Sensor::Precision"
        ::= { docsRphyRpdIfPhysEntSensorEntry 3 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB.mib
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfPhysEntSensorPrecision.
    Source version and references

    Downloaded: 2026-10-26T22:47:25.372984+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.30.1.2.2.1.1 docsRphyRpdPhysEntSensorType, docsRphyRpdIfPhysEntSensorType00
1.3.6.1.4.1.4491.2.1.30.1.2.2.1.2 docsRphyRpdPhysEntSensorScale, docsRphyRpdIfPhysEntSensorScale00
1.3.6.1.4.1.4491.2.1.30.1.2.2.1.4 docsRphyRpdPhysEntSensorValue, docsRphyRpdIfPhysEntSensorValue00
1.3.6.1.4.1.4491.2.1.30.1.2.2.1.5 docsRphyRpdPhysEntSensorOperStatus, docsRphyRpdIfPhysEntSensorOperStatus00
1.3.6.1.4.1.4491.2.1.30.1.2.2.1.6 docsRphyRpdPhysEntSensorUnitsDisplay, docsRphyRpdIfPhysEntSensorUnitsDisplay00
1.3.6.1.4.1.4491.2.1.30.1.2.2.1.7 docsRphyRpdPhysEntSensorValueTimeStamp, docsRphyRpdIfPhysEntSensorValueTimeStamp00
1.3.6.1.4.1.4491.2.1.30.1.2.2.1.8 docsRphyRpdPhysEntSensorValueUpdateRate, docsRphyRpdIfPhysEntSensorValueUpdateRate00