Reference record for OID 1.3.6.1.4.1.4491.2.1.30.1.4.10.1.7

Parent
1.3.6.1.4.1.4491.2.1.30.1.4.10.1 (docsRphyCcapCurrCtrlConnEntry)
Node code
7
Node name
docsRphyCcapCurrCtrlConnUdpPort
Numeric OID
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.7
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.30.1.4.10.1.7
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 30 1 4 10 1 7}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIpMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyCcapMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIpMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyCcapMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIpMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyCcapMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIpMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyCcapMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIpMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyCcapMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIpMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyCcapMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIpMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyCcapMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIpMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyCcapMibObjects(4) docsRphyCcapCurrCtrlConnTable(10) docsRphyCcapCurrCtrlConnEntry(1) docsRphyCcapCurrCtrlConnUdpPort(7)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/30/1/4/10/1/7
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/30/1/4/10/1/7
  • /ISO/3/6/1/4/1/4491/2/1/30/1/4/10/1/7
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIpMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyCcapMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIpMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyCcapMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIpMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyCcapMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIpMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyCcapMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIpMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyCcapMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIpMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyCcapMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIpMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyCcapMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIpMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyCcapMibObjects/docsRphyCcapCurrCtrlConnTable/docsRphyCcapCurrCtrlConnEntry/docsRphyCcapCurrCtrlConnUdpPort
  • Additional combinations skipped.

Descriptions

docsRphyCcapCurrCtrlConnUdpPort — CableLabs official current and historical MIBs

This attribute reports the UDP Port reported by the RPD when the DEPI control connection uses L2TPv3 Header Over UDP. This attribute reports a value of 0 when the control connection is running with the L2TPv3 Session IP Header.

Source records

docsRphyCcapCurrCtrlConnUdpPort

Status in source: current.

Names: docsRphyCcapCurrCtrlConnUdpPort

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyCcapCurrCtrlConnUdpPort",
    "OBJECT-TYPE",
    "SYNTAX",
    "InetPortNumber",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports the UDP Port reported by the RPD when the DEPI control connection uses L2TPv3 Header Over UDP. This attribute reports a value of 0 when the control connection is running with the L2TPv3 Session IP Header.\"",
    "REFERENCE",
    "\"Information Model Mapping: CM-SP-R-OSSI CcapCurrentControlConnections::UdpPort\"",
    "::=",
    "{",
    "docsRphyCcapCurrCtrlConnEntry",
    "7",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "InetPortNumber"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports the UDP Port reported by the RPD when the DEPI control connection uses L2TPv3 Header Over UDP. This attribute reports a value of 0 when the control connection is running with the L2TPv3 Session IP Header."
    ],
    [
      "REFERENCE",
      "Information Model Mapping: CM-SP-R-OSSI CcapCurrentControlConnections::UdpPort"
    ],
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-03-11.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-03-11.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.429401+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-10-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.003028+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-01-20.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-01-20.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.394938+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-03-31.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-03-31.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.424309+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-06-30.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.542970+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-12-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-12-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.089920+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2023-10-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['InterfaceIndex', 'TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download DOCS-RPHY-MIB-2023-10-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.579257+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2024-01-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2024-01-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.575041+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2025-01-23.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2025-01-23.txt
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.705674+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB.mib

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyCcapCurrCtrlConnUdpPort OBJECT-TYPE
        SYNTAX      InetPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION 
            "This attribute reports the UDP Port reported by the RPD 
             when the DEPI control connection uses L2TPv3 Header Over UDP. 
             This attribute reports a value of 0 when the control connection
             is running with the L2TPv3 Session IP Header."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             CcapCurrentControlConnections::UdpPort"
        ::= { docsRphyCcapCurrCtrlConnEntry 7 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB.mib
    Source location: DOCS-RPHY-MIB::docsRphyCcapCurrCtrlConnUdpPort.
    Source version and references

    Downloaded: 2026-10-26T22:47:25.372984+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Siblings (10)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.1 docsRphyCcapCurrCtrlConnLcceIpAddrType00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.2 docsRphyCcapCurrCtrlConnCcapLcceIpAddr00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.3 docsRphyCcapCurrCtrlConnRpdLcceIpAddr00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.4 docsRphyCcapCurrCtrlConnCoreConnCtrlId00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.5 docsRphyCcapCurrCtrlConnRpdConnCtrlId00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.6 docsRphyCcapCurrCtrlConnCoreId00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.8 docsRphyCcapCurrCtrlConnHaState00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.9 docsRphyCcapCurrCtrlConnSessEstFailures00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.10 docsRphyCcapCurrCtrlConnSessFailed00
1.3.6.1.4.1.4491.2.1.30.1.4.10.1.11 docsRphyCcapCurrCtrlConnCurrSess00