Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"docsRphyPtpRpdPortDataSetPortNumber",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"65535",
")",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This key attribute is the port number of the local clock port. Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. See [IEEE 1588] for more information. When a PTP clock has N ports, the CCAP Core MUST set the port number to a value in the interval 1..N.\"",
"REFERENCE",
"\"Information Model Mapping: CM-SP-R-OSSI PtpPortDataset::PortNumber\"",
"::=",
"{",
"docsRphyPtpRpdPortDataSetEntry",
"1",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
65535
]
]
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This key attribute is the port number of the local clock port. Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. See [IEEE 1588] for more information. When a PTP clock has N ports, the CCAP Core MUST set the port number to a value in the interval 1..N."
],
[
"REFERENCE",
"Information Model Mapping: CM-SP-R-OSSI PtpPortDataset::PortNumber"
],
null,
null,
null
]
}