Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"docsRphyPtpRpdPortMasterClockStatusMasterClockId",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"8",
")",
")",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This attribute specifies the clock identifier of this master clock. This value is used in Best Master Clock algorithm and is populated from the Announce message received from the master clock. This value is set to ClockIdentity from the PTP Default Dataset if no Sync messages have been received [IEEE 1588].\"",
"REFERENCE",
"\"Information Model Mapping: CM-SP-R-OSSI PtpPortMasterClockStatus::MasterClockId\"",
"::=",
"{",
"docsRphyPtpRpdPortMasterClockStatusEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This attribute specifies the clock identifier of this master clock. This value is used in Best Master Clock algorithm and is populated from the Announce message received from the master clock. This value is set to ClockIdentity from the PTP Default Dataset if no Sync messages have been received [IEEE 1588]."
],
[
"REFERENCE",
"Information Model Mapping: CM-SP-R-OSSI PtpPortMasterClockStatus::MasterClockId"
],
null,
null,
null
]
}