Reference record for OID 1.3.6.1.4.1.4491.2.1.32.1.2.5.1.1

Parent
1.3.6.1.4.1.4491.2.1.32.1.2.5.1 (docsRphyPtpCcapPortDataSetEntry)
Node code
1
Node name
docsRphyPtpCcapPortDataSetPortNumber
Numeric OID
1.3.6.1.4.1.4491.2.1.32.1.2.5.1.1
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.32.1.2.5.1.1
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 32 1 2 5 1 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyPtpMib(32) docsRphyPtpObjects(1) docsRphyPtpCcapMibObjects(2) docsRphyPtpCcapPortDataSetTable(5) docsRphyPtpCcapPortDataSetEntry(1) docsRphyPtpCcapPortDataSetPortNumber(1)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/32/1/2/5/1/1
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/32/1/2/5/1/1
  • /ISO/3/6/1/4/1/4491/2/1/32/1/2/5/1/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/identified-organization/dod/internet/private/vendor-objects/cableLabs/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/identified-organization/dod/internet/private/vendor-objects/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/org/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/org/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/org/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/org/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/org/dod/internet/private/ldap-enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/org/dod/internet/private/ldap-enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/org/dod/internet/private/vendor-objects/cableLabs/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • /iso/org/dod/internet/private/vendor-objects/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyPtpMib/docsRphyPtpObjects/docsRphyPtpCcapMibObjects/docsRphyPtpCcapPortDataSetTable/docsRphyPtpCcapPortDataSetEntry/docsRphyPtpCcapPortDataSetPortNumber
  • Additional combinations skipped.

Descriptions

docsRphyPtpCcapPortDataSetPortNumber — CableLabs official current and historical MIBs

This key attribute is the port number of the local clock port. Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. See [IEEE 1588] for more information. When a PTP clock has N ports, the CCAP Core MUST set the port number to a value in the interval 1..N.

Source records

docsRphyPtpCcapPortDataSetPortNumber

Status in source: current.

Names: docsRphyPtpCcapPortDataSetPortNumber

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyPtpCcapPortDataSetPortNumber",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This key attribute is the port number of the local clock port. Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. See [IEEE 1588] for more information. When a PTP clock has N ports, the CCAP Core MUST set the port number to a value in the interval 1..N.\"",
    "REFERENCE",
    "\"Information Model Mapping: CM-SP-R-OSSI PtpPortDataset::PortNumber\"",
    "::=",
    "{",
    "docsRphyPtpCcapPortDataSetEntry",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This key attribute is the port number of the local clock port. Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. See [IEEE 1588] for more information. When a PTP clock has N ports, the CCAP Core MUST set the port number to a value in the interval 1..N."
    ],
    [
      "REFERENCE",
      "Information Model Mapping: CM-SP-R-OSSI PtpPortDataset::PortNumber"
    ],
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2022-01-20.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
        SYNTAX        Unsigned32 (0..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "This key attribute is the port number of the local clock port. 
            Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
            See [IEEE 1588] for more information. When a PTP clock has N ports, 
            the CCAP Core MUST set the port number to a value in the interval 1..N."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             PtpPortDataset::PortNumber"    
        ::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'SNMPv2-TC': ['TruthValue', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-PTP-MIB-2022-01-20.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:50:00.464434+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2022-06-30.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
        SYNTAX        Unsigned32 (0..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "This key attribute is the port number of the local clock port. 
            Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
            See [IEEE 1588] for more information. When a PTP clock has N ports, 
            the CCAP Core MUST set the port number to a value in the interval 1..N."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             PtpPortDataset::PortNumber"    
        ::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'SNMPv2-TC': ['TruthValue', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}
    · Download DOCS-RPHY-PTP-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:50:01.047211+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB.mib

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
        SYNTAX        Unsigned32 (0..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "This key attribute is the port number of the local clock port. 
            Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
            See [IEEE 1588] for more information. When a PTP clock has N ports, 
            the CCAP Core MUST set the port number to a value in the interval 1..N."
        REFERENCE 
            "Information Model Mapping: CM-SP-R-OSSI 
             PtpPortDataset::PortNumber"    
        ::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'SNMPv2-TC': ['TruthValue', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress']}
    · Download DOCS-RPHY-PTP-MIB.mib
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:47:25.132670+00:00.

docsRphyPtpCcapPortDataSetPortNumber

Status in source: current.

Names: docsRphyPtpCcapPortDataSetPortNumber

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyPtpCcapPortDataSetPortNumber",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "(",
    "0",
    ".",
    ".",
    "65535",
    ")",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This key attribute is the port number of the local clock port. Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. See [IEEE 1588] for more information. When a PTP clock has N ports, the CCAP Core MUST set the port number to a value in the interval 1..N.\"",
    "::=",
    "{",
    "docsRphyPtpCcapPortDataSetEntry",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32",
      [
        "integerSubType",
        [
          [
            0,
            65535
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This key attribute is the port number of the local clock port. Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. See [IEEE 1588] for more information. When a PTP clock has N ports, the CCAP Core MUST set the port number to a value in the interval 1..N."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2017-04-13.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
    	SYNTAX		Unsigned32 (0..65535)
    	MAX-ACCESS	not-accessible
    	STATUS		current
    	DESCRIPTION
    		"This key attribute is the port number of the local clock port. 
    		Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
    		See [IEEE 1588] for more information. When a PTP clock has N ports, 
    		the CCAP Core MUST set the port number to a value in the interval 1..N."
    	
    	::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-PTP-MIB-2017-04-13.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.866322+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2017-08-10.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
    	SYNTAX		Unsigned32 (0..65535)
    	MAX-ACCESS	not-accessible
    	STATUS		current
    	DESCRIPTION
    		"This key attribute is the port number of the local clock port. 
    		Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
    		See [IEEE 1588] for more information. When a PTP clock has N ports, 
    		the CCAP Core MUST set the port number to a value in the interval 1..N."
    	
    	::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-PTP-MIB-2017-08-10.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:49:59.375349+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2018-04-12.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
    	SYNTAX		Unsigned32 (0..65535)
    	MAX-ACCESS	not-accessible
    	STATUS		current
    	DESCRIPTION
    		"This key attribute is the port number of the local clock port. 
    		Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
    		See [IEEE 1588] for more information. When a PTP clock has N ports, 
    		the CCAP Core MUST set the port number to a value in the interval 1..N."
    	
    	::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-PTP-MIB-2018-04-12.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:49:59.400892+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2019-01-24.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
    	SYNTAX		Unsigned32 (0..65535)
    	MAX-ACCESS	not-accessible
    	STATUS		current
    	DESCRIPTION
    		"This key attribute is the port number of the local clock port. 
    		Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
    		See [IEEE 1588] for more information. When a PTP clock has N ports, 
    		the CCAP Core MUST set the port number to a value in the interval 1..N."
    	
    	::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-PTP-MIB-2019-01-24.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:49:59.434558+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2019-06-13.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
        SYNTAX        Unsigned32 (0..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "This key attribute is the port number of the local clock port. 
            Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
            See [IEEE 1588] for more information. When a PTP clock has N ports, 
            the CCAP Core MUST set the port number to a value in the interval 1..N."
        ::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'SNMPv2-TC': ['TruthValue', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-PTP-MIB-2019-06-13.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:49:59.613188+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2020-05-21.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
        SYNTAX        Unsigned32 (0..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "This key attribute is the port number of the local clock port. 
            Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
            See [IEEE 1588] for more information. When a PTP clock has N ports, 
            the CCAP Core MUST set the port number to a value in the interval 1..N."
        ::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'SNMPv2-TC': ['TruthValue', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-PTP-MIB-2020-05-21.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:50:00.162578+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2021-03-04.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
        SYNTAX        Unsigned32 (0..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "This key attribute is the port number of the local clock port. 
            Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
            See [IEEE 1588] for more information. When a PTP clock has N ports, 
            the CCAP Core MUST set the port number to a value in the interval 1..N."
        ::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'SNMPv2-TC': ['TruthValue', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download DOCS-RPHY-PTP-MIB-2021-03-04.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:50:00.282921+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-PTP-MIB-2021-10-21.txt

    Module: DOCS-RPHY-PTP-MIB

    Published definition
    docsRphyPtpCcapPortDataSetPortNumber OBJECT-TYPE
        SYNTAX        Unsigned32 (0..65535)
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
            "This key attribute is the port number of the local clock port. 
            Port numbers 0 and 65,535 are reserved and cannot be used for real clock ports. 
            See [IEEE 1588] for more information. When a PTP clock has N ports, 
            the CCAP Core MUST set the port number to a value in the interval 1..N."
        ::= {docsRphyPtpCcapPortDataSetEntry 1}
    Module imports
    {'SNMPv2-TC': ['TruthValue', 'TimeStamp', 'DateAndTime', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter64', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-PTP-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-PTP-MIB::docsRphyPtpCcapPortDataSetPortNumber.
    Source version and references

    Downloaded: 2026-10-26T22:50:00.296218+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Siblings (2)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.32.1.2.5.1.2 docsRphyPtpCcapPortDataSetPortState00
1.3.6.1.4.1.4491.2.1.32.1.2.5.1.3 docsRphyPtpCcapPortDataSetMeanPathDelay00