Status in source: current.
Names: sfpConfigDiagnosticMonitoring
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sfpConfigDiagnosticMonitoring",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"A field with 8 single bit indicators which describe the optional digital diagnostic features implemented in the transceiver. Since transceivers will not necessarily implement all optional features described in this document, the “Enhanced Options” bit field allows the host system to determine which functions are available over the 2 wire serial bus. The bits assignment is: 7 Reserved for legacy diagnostic implementations. Must be ‘0’ for compilance with this document. 6 Digital diagnostic monitoring implemented (described in this document). Must be ‘1’ for compliance with this document. 5 Internally Calibrated 4 Externally Calibrated 3 Received power measurement type 0 = OMA, 1 = Average Power 2 Address change required.\"",
"REFERENCE",
"\"DWDM MSA Table 2.3.1 and 2.3.11, SFP-8472 Table 3.1 and 3.9.\"",
"::=",
"{",
"sfpConfigEntry",
"33",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A field with 8 single bit indicators which describe the optional digital diagnostic features implemented in the transceiver. Since transceivers will not necessarily implement all optional features described in this document, the “Enhanced Options” bit field allows the host system to determine which functions are available over the 2 wire serial bus. The bits assignment is: 7 Reserved for legacy diagnostic implementations. Must be ‘0’ for compilance with this document. 6 Digital diagnostic monitoring implemented (described in this document). Must be ‘1’ for compliance with this document. 5 Internally Calibrated 4 Externally Calibrated 3 Received power measurement type 0 = OMA, 1 = Average Power 2 Address change required."
],
[
"REFERENCE",
"DWDM MSA Table 2.3.1 and 2.3.11, SFP-8472 Table 3.1 and 3.9."
],
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: SL-SFP-MIB
Vendor MIB copy from the LibreNMS archive.
Module: SL-SFP-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'FLOAT-TC-MIB': ['Float32TC', 'Float64TC', 'Float128TC'], 'SL-ENTITY-MIB': ['CleiCode'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
· Download SL-SFP-MIB
Related source files and packages:
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: SL-SFP-MIB
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'FLOAT-TC-MIB': ['Float32TC', 'Float64TC', 'Float128TC'], 'SL-ENTITY-MIB': ['CleiCode'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
· Download SL-SFP-MIB
Related source files and packages:
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: SL-SFP-MIB
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'FLOAT-TC-MIB': ['Float32TC', 'Float64TC', 'Float128TC'], 'SL-ENTITY-MIB': ['CleiCode'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
· Download SL-SFP-MIB