The encryption capability: 1 - No Encryption. 2 - Encryption Supported.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4515.1.3.1.51
The encryption capability: 1 - No Encryption. 2 - Encryption Supported.
Identification
{1 3 6 1 4 1 4515 1 3 1 51}
Notes below names come from selected MIB definitions.
| Value | Name and source notes |
|---|---|
| 1 | disabled No Encryption |
| 2 | enabled Encryption Supported |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4515.1.3.1.51.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
slmSysEncryptionCapability OBJECT-TYPE
SYNTAX INTEGER {
disabled(1), -- No Encryption
enabled(2) -- Encryption Supported
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The encryption capability:
1 - No Encryption.
2 - Encryption Supported."
::= { slmSys 51 }slmSysEncryptionCapability OBJECT-TYPE
SYNTAX INTEGER {
disabled(1), -- No Encryption
enabled(2) -- Encryption Supported
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The encryption capability:
1 - No Encryption.
2 - Encryption Supported."
::= { slmSys 51 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The encryption capability: 1 - No Encryption. 2 - Encryption Supported.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: slmSysEncryptionCapability
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"slmSysEncryptionCapability",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"disabled",
"(",
"1",
")",
",",
"enabled",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The encryption capability: 1 - No Encryption. 2 - Encryption Supported.\"",
"::=",
"{",
"slmSys",
"51",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"disabled",
1
],
[
"enabled",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The encryption capability: 1 - No Encryption. 2 - Encryption Supported."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SL-MAIN-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'RowStatus', 'TimeStamp', 'DateAndTime'], 'SNMPv2-SMI': ['Integer32', 'IpAddress', 'Opaque', 'Gauge32', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SL-MAIN-MIB
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'RowStatus', 'TimeStamp', 'DateAndTime'], 'SNMPv2-SMI': ['Integer32', 'IpAddress', 'Opaque', 'Gauge32', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SL-MAIN-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'RowStatus', 'TimeStamp', 'DateAndTime'], 'SNMPv2-SMI': ['Integer32', 'IpAddress', 'Opaque', 'Gauge32', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount']}Registration