Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4515.1.9.1.1.1.9
Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE.
Identification
{1 3 6 1 4 1 4515 1 9 1 1 1 9}
Notes below names come from selected MIB definitions.
| Value | Name and source notes |
|---|---|
| 1 | apc automatic power control (the default) |
| 2 | agc automatic gain control |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: edfaIfIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4515.1.9.1.1.1.9
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
edfaAdminControlMode OBJECT-TYPE
SYNTAX INTEGER {
apc(1), -- automatic power control (the default)
agc(2) -- automatic gain control
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure the Edfa control mode. This object
may be set only when edfaAtomaticMode is FALSE."
::= { edfaConfigEntry 9 }edfaAdminControlMode OBJECT-TYPE
SYNTAX INTEGER {
apc(1), -- automatic power control (the default)
agc(2) -- automatic gain control
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure the Edfa control mode. This object
may be set only when edfaAtomaticMode is FALSE."
::= { edfaConfigEntry 9 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: edfaAdminControlMode
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"edfaAdminControlMode",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"apc",
"(",
"1",
")",
",",
"agc",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE.\"",
"::=",
"{",
"edfaConfigEntry",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"apc",
1
],
[
"agc",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Configure the Edfa control mode. This object may be set only when edfaAtomaticMode is FALSE."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SL-EDFA-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SL-EDFA-MIB
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SL-EDFA-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SL-NE-MIB': ['sitelight'], 'SNMPv2-TC': ['DisplayString', 'TruthValue', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Registration