boxsItemStateChangeEvent

1.3.6.1.4.1.4526.10.43.2.1

Description

This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able t…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.4526.10.43.2 (boxServicesNotificationsGroup)
Node code
1
Node name
boxsItemStateChangeEvent
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.4526.10.43.2.1
URN notation
urn:oid:1.3.6.1.4.1.4526.10.43.2.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 4526 10 43 2 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) netgear(4526) ng7000managedswitch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) netgear(4526) ng7000Switch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) netgear(4526) lb6m(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) netgear(4526) ng7000managedswitch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) netgear(4526) ng7000Switch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) netgear(4526) lb6m(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) netgear(4526) ng7000managedswitch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) netgear(4526) ng7000Switch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) netgear(4526) lb6m(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) netgear(4526) ng7000managedswitch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) netgear(4526) ng7000Switch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) netgear(4526) lb6m(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) netgear(4526) ng7000managedswitch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) netgear(4526) ng7000Switch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) netgear(4526) lb6m(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) netgear(4526) ng7000managedswitch(10) fastPathBoxServices(43) boxServicesNotificationsGroup(2) boxsItemStateChangeEvent(1)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4526/10/43/2/1
  • /ISO/Identified-Organization/6/1/4/1/4526/10/43/2/1
  • /ISO/3/6/1/4/1/4526/10/43/2/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/netgear/ng7000managedswitch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprise/netgear/ng7000Switch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprise/netgear/lb6m/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprise/netgear_1/ng7000managedswitch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprise/netgear_1/ng7000Switch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprise/netgear_1/lb6m/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprises/netgear/ng7000managedswitch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprises/netgear/ng7000Switch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprises/netgear/lb6m/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprises/netgear_1/ng7000managedswitch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprises/netgear_1/ng7000Switch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/enterprises/netgear_1/lb6m/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/netgear/ng7000managedswitch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/netgear/ng7000Switch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/netgear/lb6m/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/netgear_1/ng7000managedswitch/fastPathBoxServices/boxServicesNotificationsGroup/boxsItemStateChangeEvent
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only, accessible-for-notify
Status in MIB
current

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — NETGEAR official product and EOL MIB downloads, NETGEAR MIB copies (LibreNMS/Observium Community), and others

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 2 — NETGEAR official product and EOL MIB downloads, NETGEAR MIB copies (LibreNMS/Observium Community)

Value type
INTEGER
Maximum access defined by MIB
accessible-for-notify
Status in MIB
current

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it.

ValueNameSource variants
1insertion1, 2
2removal1, 2
3becomeoperational1, 2
4failure1, 2
5losepower2

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

A query example is omitted because the source variants do not establish compatible read access.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Product context

Documented MIB packages

The NETGEAR catalogue lists MIB files containing this definition with these product and release labels:

These are catalogue release labels, not necessarily MIB revisions. A MIB definition does not establish that a device implements it or permits access.

Available source records contain 6 distinct definitions; some records may not include a definition.

Show 6 published definitions

boxsItemStateChangeEvent · current

boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or power supply.
           
             insertion          - hot-pluggable fan or power supply was inserted
             removal            - hot-pluggable fan or power supply was removed
             becomeoperational  - fan or power supply became operational after failure state
             failure            - fan or power supply failure happened, i.e. it is not able to perform its functions"
        ::= { boxServicesNotificationsGroup 1 }

boxsItemStateChangeEvent · current

boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4)
        }
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or power supply.
           
             insertion          - hot-pluggable fan or power supply was inserted
             removal            - hot-pluggable fan or power supply was removed
             becomeoperational  - fan or power supply became operational after failure state
             failure            - fan or power supply failure happened, i.e. it is not able to perform its functions"
        ::= { boxServicesNotificationsGroup 1 }

boxsItemStateChangeEvent · current

boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4),
	     losepower(5)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or power supply.
           
             insertion          - hot-pluggable fan or power supply was inserted
             removal            - hot-pluggable fan or power supply was removed
             becomeoperational  - fan or power supply became operational after failure state
             failure            - fan or power supply failure happened, i.e. it is not able to perform its functions
             losepower          - a power supply was operational, but the power to it has been disconnected or has failed"
        ::= { boxServicesNotificationsGroup 1 }

boxsItemStateChangeEvent · current

boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4),
	     losepower(5)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or power supply.
           
             insertion          - hot-pluggable fan or power supply was inserted
             removal            - hot-pluggable fan or power supply was removed
             becomeoperational  - fan or power supply became operational after failure state
             failure            - fan or power supply failure happened, i.e. it is not able to perform its functions
             losepower          - a power supply was operational, but the power to it has been disconnected or has failed"
        ::= { boxServicesNotificationsGroup 1 }

boxsItemStateChangeEvent · current

boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4),
             losepower(5)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or Power Supply.
             insertion          - hot-pluggable fan or Power Supply was inserted
             removal            - hot-pluggable fan or Power Supply was removed
             becomeoperational  - fan or Power Supply became operational after failure state
             failure            - fan or Power Supply failure happened, i.e. it is not able to perform its functions
             losepower          - a Power Supply was operational, but the power to it has been disconnected or has failed"
        ::= { boxServicesNotificationsGroup 1 }

boxsItemStateChangeEvent · current

boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4),
             losepower(5)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or Power Supply.
             insertion          - hot-pluggable fan or Power Supply was inserted
             removal            - hot-pluggable fan or Power Supply was removed
             becomeoperational  - fan or Power Supply became operational after failure state
             failure            - fan or Power Supply failure happened, i.e. it is not able to perform its functions
             losepower          - a Power Supply was operational, but the power to it has been disconnected or has failed"
        ::= { boxServicesNotificationsGroup 1 }

Meaning

Descriptions

3 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions

Sources for this description

Netdisco MIB archive copiesNETGEAR official product and EOL MIB downloadsNETGEAR MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions losepower - a power supply was operational, but the power to it has been disconnected or has failed

Sources for this description

NETGEAR official product and EOL MIB downloadsNETGEAR MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

This event describes states of the fan or Power Supply. insertion - hot-pluggable fan or Power Supply was inserted removal - hot-pluggable fan or Power Supply was removed becomeoperational - fan or Power Supply became operational after failure state failure - fan or Power Supply failure happened, i.e. it is not able to perform its functions losepower - a Power Supply was operational, but the power to it has been disconnected or has failed

Sources for this description

NETGEAR official product and EOL MIB downloads

See 1 matching source record

Evidence

Source records

3 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Netdisco MIB archive copies, NETGEAR official product and EOL MIB downloads, and others1 record · 5 sources

Description 1

boxsItemStateChangeEvent · currentNetdisco MIB archive copies, NETGEAR official product and EOL MIB downloads, and others5 sources

Status in source: current.

Names: boxsItemStateChangeEvent

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "boxsItemStateChangeEvent",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "insertion",
    "(",
    "1",
    ")",
    ",",
    "removal",
    "(",
    "2",
    ")",
    ",",
    "becomeoperational",
    "(",
    "3",
    ")",
    ",",
    "failure",
    "(",
    "4",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions\"",
    "::=",
    "{",
    "boxServicesNotificationsGroup",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "insertion",
            1
          ],
          [
            "removal",
            2
          ],
          [
            "becomeoperational",
            3
          ],
          [
            "failure",
            4
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2NETGEAR official product and EOL MIB downloads, NETGEAR MIB copies (LibreNMS/Observium Community)1 record · 13 sources

Description 2

boxsItemStateChangeEvent · currentNETGEAR official product and EOL MIB downloads, NETGEAR MIB copies (LibreNMS/Observium Community)13 sources

Status in source: current.

Names: boxsItemStateChangeEvent

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "boxsItemStateChangeEvent",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "insertion",
    "(",
    "1",
    ")",
    ",",
    "removal",
    "(",
    "2",
    ")",
    ",",
    "becomeoperational",
    "(",
    "3",
    ")",
    ",",
    "failure",
    "(",
    "4",
    ")",
    ",",
    "losepower",
    "(",
    "5",
    ")",
    "}",
    "MAX-ACCESS",
    "accessible-for-notify",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions losepower - a power supply was operational, but the power to it has been disconnected or has failed\"",
    "::=",
    "{",
    "boxServicesNotificationsGroup",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "insertion",
            1
          ],
          [
            "removal",
            2
          ],
          [
            "becomeoperational",
            3
          ],
          [
            "failure",
            4
          ],
          [
            "losepower",
            5
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "accessible-for-notify"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions losepower - a power supply was operational, but the power to it has been disconnected or has failed"
    ],
    null,
    null,
    null,
    null
  ]
}

Browse all 13 supporting sources

Records for description 3NETGEAR official product and EOL MIB downloads1 record · 5 sources

Description 3

boxsItemStateChangeEvent · currentNETGEAR official product and EOL MIB downloads5 sources

Status in source: current.

Names: boxsItemStateChangeEvent

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "boxsItemStateChangeEvent",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "insertion",
    "(",
    "1",
    ")",
    ",",
    "removal",
    "(",
    "2",
    ")",
    ",",
    "becomeoperational",
    "(",
    "3",
    ")",
    ",",
    "failure",
    "(",
    "4",
    ")",
    ",",
    "losepower",
    "(",
    "5",
    ")",
    "}",
    "MAX-ACCESS",
    "accessible-for-notify",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This event describes states of the fan or Power Supply. insertion - hot-pluggable fan or Power Supply was inserted removal - hot-pluggable fan or Power Supply was removed becomeoperational - fan or Power Supply became operational after failure state failure - fan or Power Supply failure happened, i.e. it is not able to perform its functions losepower - a Power Supply was operational, but the power to it has been disconnected or has failed\"",
    "::=",
    "{",
    "boxServicesNotificationsGroup",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "insertion",
            1
          ],
          [
            "removal",
            2
          ],
          [
            "becomeoperational",
            3
          ],
          [
            "failure",
            4
          ],
          [
            "losepower",
            5
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "accessible-for-notify"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This event describes states of the fan or Power Supply. insertion - hot-pluggable fan or Power Supply was inserted removal - hot-pluggable fan or Power Supply was removed becomeoperational - fan or Power Supply became operational after failure state failure - fan or Power Supply failure happened, i.e. it is not able to perform its functions losepower - a Power Supply was operational, but the power to it has been disconnected or has failed"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4526)

Michael Shields

Siblings (3)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4526.10.43.2.2 boxsTemperatureChangeEvent00
1.3.6.1.4.1.4526.10.43.2.3 boxsTemperatureStatusCurrentEvent00
1.3.6.1.4.1.4526.10.43.2.4 boxsTemperatureStatusPreviousEvent00