Indicates the inserted card type. Will return 0 if the slot is not full.
Sources for this description
Netdisco MIB archive copiesNETGEAR official product and EOL MIB downloads
OID reference
1.3.6.1.4.1.4526.11.13.3.1.1.6
Indicates the inserted card type. Will return 0 if the slot is not full.
Identification
{1 3 6 1 4 1 4526 11 13 3 1 1 6}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
The NETGEAR catalogue lists MIB files containing this definition with these product and release labels:
These are catalogue release labels, not necessarily MIB revisions. A MIB definition does not establish that a device implements it or permits access.
Available source records contain 2 distinct definitions; some records may not include a definition.
agentInventorySlotInsertedCardType OBJECT-TYPE
SYNTAX AgentInventoryCardType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the inserted card type. Will return 0 if the slot is
not full."
::= { agentInventorySlotEntry 6 }agentInventorySlotInsertedCardType OBJECT-TYPE
SYNTAX AgentInventoryCardType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the inserted card type. Will return 0 if the slot is
not full."
::= { agentInventorySlotEntry 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates the inserted card type. Will return 0 if the slot is not full.
Netdisco MIB archive copiesNETGEAR official product and EOL MIB downloads
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: agentInventorySlotInsertedCardType
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"agentInventorySlotInsertedCardType",
"OBJECT-TYPE",
"SYNTAX",
"AgentInventoryCardType",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates the inserted card type. Will return 0 if the slot is not full.\"",
"::=",
"{",
"agentInventorySlotEntry",
"6",
"}"
],
"syntax_tree": [
[
"row",
"AgentInventoryCardType"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates the inserted card type. Will return 0 if the slot is not full."
],
null,
null,
null,
null
]
}Module: NETGEAR-INVENTORY-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NETGEAR-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Same file in fs728tp_5.0.2.50-mibs.zip.
Module: NETGEAR-INVENTORY-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NETGEAR-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Module: FASTPATH-INVENTORY-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'BROADCOM-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Same file in gs7xxts_tps-v5.3.0.31-mibs.zip.
Module: FASTPATH-INVENTORY-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'BROADCOM-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Same file in gs7xxts_tps-v5.3.0.36-mibs.zip.
Module: NETGEAR-INVENTORY-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NETGEAR-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Same file in gs7xxtxs-v6.1.0.36-mibs.zip.
Module: NETGEAR-INVENTORY-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NETGEAR-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Module: NETGEAR-INVENTORY-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NETGEAR-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Module: NETGEAR-INVENTORY-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NETGEAR-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Same file in s3300-v6.6.1.7-mibs.zip.
Same file in s3300-v6.6.1.4-mibs.tar.bz2.
Module: NETGEAR-INVENTORY-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NETGEAR-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Same file in s3300v6.6.4.9-mibs.zip.
Same file in s3300v6.6.4.28-mibs.zip.
Module: NETGEAR-INVENTORY-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Gauge32', 'Counter32', 'Unsigned32', 'TimeTicks', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'NETGEAR-REF-MIB': ['ng700smartswitch']}Related source files and packages:
Same file in s3300v6.6.4.26-mibs.zip.
Same file in s3300v6.6.4.25-mibs.zip.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4526.11.13.3.1.1.1 | agentInventorySlotNumber | 0 | 0 | |
| 1.3.6.1.4.1.4526.11.13.3.1.1.3 | agentInventorySlotStatus | 0 | 0 | |
| 1.3.6.1.4.1.4526.11.13.3.1.1.4 | agentInventorySlotPowerMode | 0 | 0 | |
| 1.3.6.1.4.1.4526.11.13.3.1.1.5 | agentInventorySlotAdminMode | 0 | 0 | |
| 1.3.6.1.4.1.4526.11.13.3.1.1.7 | agentInventorySlotConfiguredCardType | 0 | 0 | |
| 1.3.6.1.4.1.4526.11.13.3.1.1.8 | agentInventorySlotCapabilities | 0 | 0 |