Remaining time in current OSPF graceful restart interval.
Sources for this description
NETGEAR MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4526.17.210.2.1.23
Remaining time in current OSPF graceful restart interval.
Identification
{1 3 6 1 4 1 4526 17 210 2 1 23}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: rlOspfProcessId.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4526.17.210.2.1.23
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlOspfRestartAge OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remaining time in current OSPF graceful restart
interval."
::= { rlOspfGeneralGroupEntry 23 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Remaining time in current OSPF graceful restart interval.
NETGEAR MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlOspfRestartAge
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlOspfRestartAge",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"UNITS",
[
"literal",
"227365636f6e647322"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Remaining time in current OSPF graceful restart interval.\"",
"::=",
"{",
"rlOspfGeneralGroupEntry",
"23",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
[
"UNITS",
"seconds"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Remaining time in current OSPF graceful restart interval."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. NETGEAR support.
Module: NETGEAR-RADLAN-OSPF-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero'], 'OSPF-MIB': ['AreaID', 'RouterID', 'Metric', 'BigMetric', 'Status', 'PositiveInteger', 'HelloRange', 'UpToMaxAge', 'DesignatedRouterPriority', 'TOSType'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['mib-2'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'NETGEAR-RADLAN-MIB': ['rnd']}Related source files and packages:
Registration