The IPv6 address of the host. Must be an IPv6 global address.
Sources for this description
NETGEAR MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4526.17.216.7.1.3
The IPv6 address of the host. Must be an IPv6 global address.
Identification
{1 3 6 1 4 1 4526 17 216 7 1 3}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlOspfv3HostAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IPv6 address of the host. Must be an
IPv6 global address."
REFERENCE
"OSPF Version 2, Appendix C.7, Host route
parameters"
::= { rlOspfv3HostEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The IPv6 address of the host. Must be an IPv6 global address.
NETGEAR MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlOspfv3HostAddress
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlOspfv3HostAddress",
"OBJECT-TYPE",
"SYNTAX",
"InetAddress",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The IPv6 address of the host. Must be an IPv6 global address.\"",
"REFERENCE",
"\"OSPF Version 2, Appendix C.7, Host route parameters\"",
"::=",
"{",
"rlOspfv3HostEntry",
"3",
"}"
],
"syntax_tree": [
[
"row",
"InetAddress"
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The IPv6 address of the host. Must be an IPv6 global address."
],
[
"REFERENCE",
"OSPF Version 2, Appendix C.7, Host route parameters"
],
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. NETGEAR support.
Module: NETGEAR-RADLAN-OSPFV3-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'OSPF-MIB': ['AreaID', 'RouterID', 'Metric', 'BigMetric', 'Status', 'PositiveInteger', 'UpToMaxAge', 'TOSType', 'OspfAuthenticationType', 'HelloRange', 'DesignatedRouterPriority'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp', 'DisplayString'], 'OSPFV3-MIB': ['Ospfv3UpToRefreshIntervalTC', 'Ospfv3DeadIntervalRangeTC', 'Ospfv3RouterIdTC', 'Ospfv3LsIdTC', 'Ospfv3AreaIdTC', 'Ospfv3IfInstIdTC', 'Ospfv3LsaSequenceTC', 'Ospfv3LsaAgeTC'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'mib-2', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['mib-2'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength', 'InetAddressIPv6'], 'NETGEAR-RADLAN-MIB': ['rnd'], 'NETGEAR-RADLAN-OSPF-MIB': ['RlOspfProcessID', 'RlOspfFastHelloMultiplierRange', 'RlOspfRestartHelperStatus', 'RlOspfRestartExitReason', 'RlOspfRouterIdType']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4526.17.216.7.1.1 | rlOspfv3HostProcessId | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.216.7.1.2 | rlOspfv3HostAddressType | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.216.7.1.4 | rlOspfv3HostMetric | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.216.7.1.5 | rlOspfv3HostRowStatus | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.216.7.1.6 | rlOspfv3HostAreaID | 0 | 0 |