The value of the monitored object instance, the exceeding of which will cause the generation of an alarm to the high-level management station.
Sources for this description
NETGEAR MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4526.17.35.2.4.1.8
The value of the monitored object instance, the exceeding of which will cause the generation of an alarm to the high-level management station.
Identification
{1 3 6 1 4 1 4526 17 35 2 4 1 8}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: rndMonitoredElement, IMPLIED rndMonitoredObjectInstanceLabel.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4526.17.35.2.4.1.8
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rndAlarmMaxTreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the monitored object instance, the exceeding of which
will cause the generation of an alarm to the high-level management
station."
::= {rndMonitoringEntry 8}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The value of the monitored object instance, the exceeding of which will cause the generation of an alarm to the high-level management station.
NETGEAR MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rndAlarmMaxTreshold
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rndAlarmMaxTreshold",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of the monitored object instance, the exceeding of which will cause the generation of an alarm to the high-level management station.\"",
"::=",
"{",
"rndMonitoringEntry",
"8",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of the monitored object instance, the exceeding of which will cause the generation of an alarm to the high-level management station."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. NETGEAR support.
Module: NETGEAR-RADLAN-rndApplications
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'InterfaceIndex', 'ifIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'TruthValue'], 'SNMPv2-SMI': ['Unsigned32', 'Counter32', 'IpAddress', 'MODULE-IDENTITY', 'OBJECT-TYPE'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'NETGEAR-RADLAN-MIB': ['rnd']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4526.17.35.2.4.1.1 | rndMonitoredElement | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.2 | rndMonitoredObjectInstanceLabel | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.3 | rndMonitoredObjectName | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.4 | rndMonitoredObjectIdentifier | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.5 | rndMonitoredObjectInstance | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.6 | rndMonitoredObjectSyntax | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.7 | rndMonitoringInterval | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.9 | rndAlarmMinTreshold | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.10 | rndMonitoringLogfile | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.11 | rndMonitoringEntryStatus | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.35.2.4.1.12 | rndMonitoredIntegerInstance | 0 | 0 |