The tagged value of the port. When the Tagged field is not a part of the FFT table in the ASIC, the Tagged field get the BasedPortConfig value.
Sources for this description
NETGEAR MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4526.17.47.1.17.1.9
The tagged value of the port. When the Tagged field is not a part of the FFT table in the ASIC, the Tagged field get the BasedPortConfig value.
Identification
{1 3 6 1 4 1 4526 17 47 1 17 1 9}
| Value | Name |
|---|---|
| 1 | untagged |
| 2 | tagged |
| 3 | basedPortConfig |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: rlInetFftL2InfoIfindex, rlInetFftL2InfoDstMacAddress.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4526.17.47.1.17.1.9
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlInetFftL2InfoTaggedMode OBJECT-TYPE
SYNTAX INTEGER {
untagged (1),
tagged (2),
basedPortConfig (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tagged value of the port. When the Tagged field is not
a part of the FFT table in the ASIC,
the Tagged field get the BasedPortConfig value."
::= { rlInetFftL2InfoEntry 9 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The tagged value of the port. When the Tagged field is not a part of the FFT table in the ASIC, the Tagged field get the BasedPortConfig value.
NETGEAR MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlInetFftL2InfoTaggedMode
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlInetFftL2InfoTaggedMode",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"untagged",
"(",
"1",
")",
",",
"tagged",
"(",
"2",
")",
",",
"basedPortConfig",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The tagged value of the port. When the Tagged field is not a part of the FFT table in the ASIC, the Tagged field get the BasedPortConfig value.\"",
"::=",
"{",
"rlInetFftL2InfoEntry",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"untagged",
1
],
[
"tagged",
2
],
[
"basedPortConfig",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The tagged value of the port. When the Tagged field is not a part of the FFT table in the ASIC, the Tagged field get the BasedPortConfig value."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. NETGEAR support.
Module: NETGEAR-RADLAN-rlFft
See published definition above
{'SNMPv2-TC': ['RowStatus', 'TruthValue', 'PhysAddress', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['Unsigned32', 'IpAddress', 'MODULE-IDENTITY', 'OBJECT-TYPE'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetAddressPrefixLength'], 'NETGEAR-RADLAN-MIB': ['rnd']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4526.17.47.1.17.1.1 | rlInetFftL2InfoIfindex | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.47.1.17.1.2 | rlInetFftL2InfoDstMacAddress | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.47.1.17.1.3 | rlInetFftL2InfoValid | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.47.1.17.1.4 | rlInetFftL2InfoType | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.47.1.17.1.5 | rlInetFftL2InfoReferenceCount | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.47.1.17.1.6 | rlInetFftL2InfoVid | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.47.1.17.1.7 | rlInetFftL2InfoSrcMacAddress | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.47.1.17.1.8 | rlInetFftL2InfoOutIfIndex | 0 | 0 |