RCLI Configuration File action determines whether The device configuration after reset will be set by the configuration file content or not.
Sources for this description
NETGEAR MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4526.17.70.6
RCLI Configuration File action determines whether The device configuration after reset will be set by the configuration file content or not.
Identification
{1 3 6 1 4 1 4526 17 70 6}
| Value | Name |
|---|---|
| 1 | notUsedAfterReset |
| 2 | usedAfterReset |
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlRcliFileAction OBJECT-TYPE
SYNTAX INTEGER {
notUsedAfterReset(1),
usedAfterReset (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RCLI Configuration File action determines whether
The device configuration after reset will be set by
the configuration file content or not."
::= { rlRCli 6 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
RCLI Configuration File action determines whether The device configuration after reset will be set by the configuration file content or not.
NETGEAR MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlRcliFileAction
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlRcliFileAction",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"notUsedAfterReset",
"(",
"1",
")",
",",
"usedAfterReset",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"RCLI Configuration File action determines whether The device configuration after reset will be set by the configuration file content or not.\"",
"::=",
"{",
"rlRCli",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"notUsedAfterReset",
1
],
[
"usedAfterReset",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"RCLI Configuration File action determines whether The device configuration after reset will be set by the configuration file content or not."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. NETGEAR support.
Module: NETGEAR-RADLAN-RCLI-MIB
See published definition above
{'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY'], 'NETGEAR-RADLAN-MIB': ['rnd']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4526.17.70.1 | rlRCliMibVersion | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.70.2 | rlRCliUserPassword | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.70.3 | rlRCliEnablePassword | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.70.4 | rlRCliConfigPassword | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.70.5 | rlRCliTimer | 0 | 0 |