Writing a value to this leaf results in a test being run on the host.
Sources for this description
NETGEAR MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4526.17.82.3.1
Writing a value to this leaf results in a test being run on the host.
Identification
{1 3 6 1 4 1 4526 17 82 3 1}
| Value | Name |
|---|---|
| 11 | successfulRegistration |
| 12 | regTheSameComponentTwice |
| 13 | regWithInvalidComponentID |
| 14 | regWithInvalidApplicationID |
| 15 | regWithInvalidMessageString |
| 16 | regWithInvalidMessageList |
| 17 | regWithInvalidApplicationList |
| 21 | successfulLoggingWithNoParams |
| 22 | logWithUnregisteredComponentID |
| 23 | logWithInvalidComponentID |
| 24 | logWithBadApplicationID |
| 25 | logWithBadMessageID |
| 31 | paramFormatting |
| 32 | insufficientParams |
| 33 | incorrectParams |
| 34 | tooManyParams |
| 35 | oversizedParams |
| 36 | trapParams |
| 41 | successfulFatalError |
| 42 | fatalErrorThroughNonFatalInterface |
| 43 | nonFatalErrorThroughFatalInterface |
| 47 | nestedFatalErrors |
| 62 | snmpAccessToLongMessage |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4526.17.82.3.1.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlSyslogPhaseOneTestGenerator OBJECT-TYPE
SYNTAX INTEGER {
successfulRegistration(11),
regTheSameComponentTwice (12),
regWithInvalidComponentID(13),
regWithInvalidApplicationID(14),
regWithInvalidMessageString(15),
regWithInvalidMessageList(16),
regWithInvalidApplicationList(17),
successfulLoggingWithNoParams(21),
logWithUnregisteredComponentID(22),
logWithInvalidComponentID(23),
logWithBadApplicationID(24),
logWithBadMessageID(25),
paramFormatting(31),
insufficientParams(32),
incorrectParams(33),
tooManyParams(34),
oversizedParams(35),
trapParams(36),
successfulFatalError(41),
fatalErrorThroughNonFatalInterface(42),
nonFatalErrorThroughFatalInterface(43),
nestedFatalErrors(47),
snmpAccessToLongMessage(62)
}
-- todo: once we have all of the tests, change them into an enum.
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing a value to this leaf results in a test being run on the host."
::= { rlSyslogPhaseOneTests 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Writing a value to this leaf results in a test being run on the host.
NETGEAR MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlSyslogPhaseOneTestGenerator
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlSyslogPhaseOneTestGenerator",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"successfulRegistration",
"(",
"11",
")",
",",
"regTheSameComponentTwice",
"(",
"12",
")",
",",
"regWithInvalidComponentID",
"(",
"13",
")",
",",
"regWithInvalidApplicationID",
"(",
"14",
")",
",",
"regWithInvalidMessageString",
"(",
"15",
")",
",",
"regWithInvalidMessageList",
"(",
"16",
")",
",",
"regWithInvalidApplicationList",
"(",
"17",
")",
",",
"successfulLoggingWithNoParams",
"(",
"21",
")",
",",
"logWithUnregisteredComponentID",
"(",
"22",
")",
",",
"logWithInvalidComponentID",
"(",
"23",
")",
",",
"logWithBadApplicationID",
"(",
"24",
")",
",",
"logWithBadMessageID",
"(",
"25",
")",
",",
"paramFormatting",
"(",
"31",
")",
",",
"insufficientParams",
"(",
"32",
")",
",",
"incorrectParams",
"(",
"33",
")",
",",
"tooManyParams",
"(",
"34",
")",
",",
"oversizedParams",
"(",
"35",
")",
",",
"trapParams",
"(",
"36",
")",
",",
"successfulFatalError",
"(",
"41",
")",
",",
"fatalErrorThroughNonFatalInterface",
"(",
"42",
")",
",",
"nonFatalErrorThroughFatalInterface",
"(",
"43",
")",
",",
"nestedFatalErrors",
"(",
"47",
")",
",",
"snmpAccessToLongMessage",
"(",
"62",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Writing a value to this leaf results in a test being run on the host.\"",
"::=",
"{",
"rlSyslogPhaseOneTests",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"successfulRegistration",
11
],
[
"regTheSameComponentTwice",
12
],
[
"regWithInvalidComponentID",
13
],
[
"regWithInvalidApplicationID",
14
],
[
"regWithInvalidMessageString",
15
],
[
"regWithInvalidMessageList",
16
],
[
"regWithInvalidApplicationList",
17
],
[
"successfulLoggingWithNoParams",
21
],
[
"logWithUnregisteredComponentID",
22
],
[
"logWithInvalidComponentID",
23
],
[
"logWithBadApplicationID",
24
],
[
"logWithBadMessageID",
25
],
[
"paramFormatting",
31
],
[
"insufficientParams",
32
],
[
"incorrectParams",
33
],
[
"tooManyParams",
34
],
[
"oversizedParams",
35
],
[
"trapParams",
36
],
[
"successfulFatalError",
41
],
[
"fatalErrorThroughNonFatalInterface",
42
],
[
"nonFatalErrorThroughFatalInterface",
43
],
[
"nestedFatalErrors",
47
],
[
"snmpAccessToLongMessage",
62
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Writing a value to this leaf results in a test being run on the host."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. NETGEAR support.
Module: NETGEAR-RADLAN-SYSLOG-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'Counter32', 'MODULE-IDENTITY'], 'NETGEAR-RADLAN-MIB': ['rnd']}Related source files and packages:
Registration