Daylight Saving Time - The number of minutes to add to the clock during summer time.
Sources for this description
NETGEAR MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4526.17.92.1.11
Daylight Saving Time - The number of minutes to add to the clock during summer time.
Identification
{1 3 6 1 4 1 4526 17 92 1 11}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4526.17.92.1.11.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlDaylightSavingTimeOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Daylight Saving Time - The number of minutes to add to
the clock during summer time."
DEFVAL { 60 }
::= { rlTimeSyncMethodMode 11 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Daylight Saving Time - The number of minutes to add to the clock during summer time.
NETGEAR MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlDaylightSavingTimeOffset
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlDaylightSavingTimeOffset",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Daylight Saving Time - The number of minutes to add to the clock during summer time.\"",
"DEFVAL",
"{",
"60",
"}",
"::=",
"{",
"rlTimeSyncMethodMode",
"11",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Daylight Saving Time - The number of minutes to add to the clock during summer time."
],
null,
null,
null,
[
"DEFVAL",
60
]
]
}Vendor MIB copy from the Observium Community archive. NETGEAR support.
Module: NETGEAR-RADLAN-TIMESYNCHRONIZATION-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'RowStatus', 'TruthValue'], 'SNMPv2-SMI': ['Unsigned32', 'Integer32', 'IpAddress', 'MODULE-IDENTITY', 'OBJECT-TYPE'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'NETGEAR-RADLAN-MIB': ['rnd']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4526.17.92.1.1 | rlTimeSyncMibVersion | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.2 | rndTimeSyncManagedTime | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.3 | rndTimeSyncManagedDate | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.4 | rndTimeSyncManagedDateTime | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.5 | rlTimeSyncMethod | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.6 | rlTimeZone | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.7 | rlTimeZoneCode | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.8 | rlDaylightSavingTimeMode | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.9 | rlDaylightSavingTimeStart | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.10 | rlDaylightSavingTimeEnd | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.12 | rlDaylightSavingTimeCode | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.13 | rlTZDSTOffset | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.14 | rlTimeZoneName | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.15 | rlTimeZoneTable | 1 | 15 | |
| 1.3.6.1.4.1.4526.17.92.1.16 | rlClockStatus | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.17 | rlDhcpTimezoneOptionEnabled | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.18 | rlAutomaticClockSetFromPCEnabled | 0 | 0 | |
| 1.3.6.1.4.1.4526.17.92.1.19 | rlTimeAndDateHaveBeenSet | 0 | 0 |