This object set the delay time (in seconds) to turn UPS off after Net Vision broadcast shutdown request to connected clients
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4555.1.1.1.1.8.2
This object set the delay time (in seconds) to turn UPS off after Net Vision broadcast shutdown request to connected clients
Identification
{1 3 6 1 4 1 4555 1 1 1 1 8 2}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4555.1.1.1.1.8.2.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
upsShutdownDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object set the delay time (in seconds) to turn UPS off after
Net Vision broadcast shutdown request to connected clients"
::= { upsControl 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object set the delay time (in seconds) to turn UPS off after Net Vision broadcast shutdown request to connected clients
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: upsShutdownDelay
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"upsShutdownDelay",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"This object set the delay time (in seconds) to turn UPS off after Net Vision broadcast shutdown request to connected clients\"",
"::=",
"{",
"upsControl",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"This object set the delay time (in seconds) to turn UPS off after Net Vision broadcast shutdown request to connected clients"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SOCOMECUPS-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4555.1.1.1.1.8.1 | upsControlStatusControl | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.1.1.8.3 | upsTurnOffAfterShutdown | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.1.1.8.4 | upsControlShutdownParametersTable | 1 | 6 | |
| 1.3.6.1.4.1.4555.1.1.1.1.8.5 | upsControlWeeklyScheduleTable | 1 | 6 | |
| 1.3.6.1.4.1.4555.1.1.1.1.8.6 | upsControlSpecialScheduleTable | 1 | 6 | |
| 1.3.6.1.4.1.4555.1.1.1.1.8.7 | upsControlEcoModeScheduleTable | 1 | 6 |