OID reference

upsControlWarningInterval

1.3.6.1.4.1.4555.1.1.1.1.8.4.1.5

Description

The frequency of sending warning messages to the connected clients when the curresponding shutdown event occurs. The value is in units of seconds.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.4555.1.1.1.1.8.4.1 (shutdownParametersEntry)
Node code
5
Node name
upsControlWarningInterval
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.4555.1.1.1.1.8.4.1.5
URN notation
urn:oid:1.3.6.1.4.1.4555.1.1.1.1.8.4.1.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 4555 1 1 1 1 8 4 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomec(4555) software(1) network(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomec(4555) software(1) pduAgent(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomec(4555) product(1) network(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomec(4555) product(1) pduAgent(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomecUPS(4555) software(1) network(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomecUPS(4555) software(1) pduAgent(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomecUPS(4555) product(1) network(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomecUPS(4555) product(1) pduAgent(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomecSicon(4555) software(1) network(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomecSicon(4555) software(1) pduAgent(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomecSicon(4555) product(1) network(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) socomecSicon(4555) product(1) pduAgent(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) socomec(4555) software(1) network(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) socomec(4555) software(1) pduAgent(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) socomec(4555) product(1) network(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) socomec(4555) product(1) pduAgent(1) netvision(1) upsObjects(1) upsControl(8) upsControlShutdownParametersTable(4) shutdownParametersEntry(1) upsControlWarningInterval(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4555/1/1/1/1/8/4/1/5
  • /ISO/Identified-Organization/6/1/4/1/4555/1/1/1/1/8/4/1/5
  • /ISO/3/6/1/4/1/4555/1/1/1/1/8/4/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/4555/software/network/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/4555/software/pduAgent/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/4555/product/network/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/4555/product/pduAgent/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomec/software/network/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomec/software/pduAgent/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomec/product/network/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomec/product/pduAgent/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomecUPS/software/network/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomecUPS/software/pduAgent/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomecUPS/product/network/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomecUPS/product/pduAgent/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomecSicon/software/network/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomecSicon/software/pduAgent/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomecSicon/product/network/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • /iso/identified-organization/dod/internet/private/enterprise/socomecSicon/product/pduAgent/netvision/upsObjects/upsControl/upsControlShutdownParametersTable/shutdownParametersEntry/upsControlWarningInterval
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Allowed ranges
0–32767

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: upsControlEventDescr.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4555.1.1.1.1.8.4.1.5

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

upsControlWarningInterval OBJECT-TYPE
        SYNTAX INTEGER (0..32767)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The frequency of sending warning messages to the connected
                clients when the curresponding shutdown event occurs.
                The value is in units of seconds."
                ::= { shutdownParametersEntry 5 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The frequency of sending warning messages to the connected clients when the curresponding shutdown event occurs. The value is in units of seconds.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

upsControlWarningInterval · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: mandatory.

Names: upsControlWarningInterval

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsControlWarningInterval",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "32767",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"The frequency of sending warning messages to the connected clients when the curresponding shutdown event occurs. The value is in units of seconds.\"",
    "::=",
    "{",
    "shutdownParametersEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            32767
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "The frequency of sending warning messages to the connected clients when the curresponding shutdown event occurs. The value is in units of seconds."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4555)

Ivo Pancheri

Siblings (4)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4555.1.1.1.1.8.4.1.1 upsControlEventDescr00
1.3.6.1.4.1.4555.1.1.1.1.8.4.1.2 upsControlEventStatus00
1.3.6.1.4.1.4555.1.1.1.1.8.4.1.3 upsControlDelay00
1.3.6.1.4.1.4555.1.1.1.1.8.4.1.4 upsControlFirstWarning00