The UPS output is in standby, and the UPS is awaiting the return of input power.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4555.1.1.7.1.6.3.62
The UPS output is in standby, and the UPS is awaiting the return of input power.
Identification
{1 3 6 1 4 1 4555 1 1 7 1 6 3 62}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4555.1.1.7.1.6.3.62.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
upsAlarmAwaitingPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS output is in standby,
and the UPS is awaiting the return of input power."
::= { upsWellKnownAlarms 62 }upsAlarmAwaitingPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS output is in standby,
and the UPS is awaiting the return of input power."
::= { upsWellKnownAlarms 62 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The UPS output is in standby, and the UPS is awaiting the return of input power.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: upsAlarmAwaitingPower
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"upsAlarmAwaitingPower",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The UPS output is in standby, and the UPS is awaiting the return of input power.\"",
"::=",
"{",
"upsWellKnownAlarms",
"62",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The UPS output is in standby, and the UPS is awaiting the return of input power."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: SOCOMECUPS-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: SOCOMECUPS7-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.51 | upsAlarmModule10Alarm | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.52 | upsAlarmModule11Alarm | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.53 | upsAlarmModule12Alarm | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.54 | upsAlarmAutoTestRunning | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.55 | upsAlarmOnBypass | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.56 | upsAlarmUpsOutputOff | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.57 | upsAlarmUpsSystemOff | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.58 | upsAlarmCommunicationLost | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.59 | upsAlarmShutdownPending | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.60 | upsAlarmShutdownRequestt | 0 | 0 | |
| 1.3.6.1.4.1.4555.1.1.7.1.6.3.61 | upsAlarmShutdownImminent | 0 | 0 |