High temperature alarm limit 3
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.46651.1.11.9
High temperature alarm limit 3
Identification
{1 3 6 1 4 1 46651 1 11 9}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.46651.1.11.9.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
temprHighlimit3sys OBJECT-TYPE
SYNTAX INTEGER(-40..80)
UNITS "celsius"
ACCESS read-write
STATUS mandatory
DESCRIPTION " High temperature alarm limit 3 "
::= { systemConfig 9 }temprHighlimit3sys OBJECT-TYPE
SYNTAX INTEGER(-40..80)
ACCESS read-write
STATUS mandatory
DESCRIPTION " High temperature alarm limit 3 "
::= { systemConfig 9 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
High temperature alarm limit 3
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: temprHighlimit3sys
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"temprHighlimit3sys",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"-",
"40",
".",
".",
"80",
")",
"UNITS",
[
"literal",
"2263656c7369757322"
],
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\" High temperature alarm limit 3 \"",
"::=",
"{",
"systemConfig",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
-40,
80
]
]
]
],
[
"UNITS",
"celsius"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"High temperature alarm limit 3"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: DANTHERM-COOLING-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['enterprises']}Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.
· Download DANTHERM-COOLING-MIBRelated source files and packages:
Status in source: mandatory.
Names: temprHighlimit3sys
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"temprHighlimit3sys",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"-",
"40",
".",
".",
"80",
")",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\" High temperature alarm limit 3 \"",
"::=",
"{",
"systemConfig",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
-40,
80
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"High temperature alarm limit 3"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: DANTHERM-COOLING-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['enterprises']}Related source files and packages: