Power supply AC lost.
Sources for this description
Cohesity appliance MIB copy (PySNMP archive)
OID reference
1.3.6.1.4.1.47421.0.27
Power supply AC lost.
Identification
{1 3 6 1 4 1 47421 0 27}
The displayed source records contain one distinct definition. Compare its source records.
powerSupplyAcLostNotif NOTIFICATION-TYPE
OBJECTS { powerSupplyAcLostEvent }
STATUS current
DESCRIPTION
"Power supply AC lost."
::= { caNotifsGroup 27 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Power supply AC lost.
Cohesity appliance MIB copy (PySNMP archive)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: powerSupplyAcLostNotif
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"powerSupplyAcLostNotif",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"powerSupplyAcLostEvent",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Power supply AC lost.\"",
"::=",
"{",
"caNotifsGroup",
"27",
"}"
],
"syntax_tree": [
[
"Objects",
[
"powerSupplyAcLostEvent"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Power supply AC lost."
],
null
]
}Module: COHESITY-APPLIANCE-MIB
See published definition above
{'SNMPv2-TC': ['PhysAddress', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'Integer32', 'Gauge32', 'Counter32', 'Counter64', 'TimeTicks', 'IpAddress', 'Opaque'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'IANAifType-MIB': ['IANAifType']}Source data warning: This is a third-party PySNMP archive copy attributed to Cohesity. The original manufacturer distribution and applicability to particular software versions have not been independently confirmed. The file identifies its revision as 202409270532Z. OpsRamp reports a newer revision dated 202501030136Z; its original file has not been obtained.
· Download Cohesity appliance MIB — PySNMP archive copy, revision 202409270532ZRegistration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.47421.0.1 | diskNotHealthyNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.2 | nodePingFailedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.3 | markDiskForRemovalNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.4 | upgradeFailedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.5 | newDiskFoundNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.6 | diskSpaceLowNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.7 | timeServiceNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.8 | missingDiskNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.9 | writeLimitNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.10 | memUncorrectableEccNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.12 | watchdogTriggeredNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.13 | tempOutOfHighRangeNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.14 | tempOutOfLowRangeNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.15 | voltOutOfHighRangeNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.16 | voltOutOfLowRangeNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.17 | driveRemovedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.18 | drivePresentNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.19 | driveFaultNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.20 | powerSupplyRemovedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.21 | powerSupplyInsertedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.22 | linkIsDownNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.23 | linkIsUpNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.24 | ipmiSelClearedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.25 | nodeRebootedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.26 | thermalTripTriggeredNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.28 | nodeChassisChangedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.29 | raidDegradedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.30 | diskAddedToClusterNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.31 | systemLedAmberNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.32 | cpuThrottledNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.33 | fanRemovedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.34 | fanInsertedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.35 | fanSpeedOutOfLowRangeNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.36 | chassisDownNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.37 | ipmiUnreachableNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.38 | ipmiNetworkConfigFailedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.39 | ipmiUserUpdateFailedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.40 | ipmiConfigAbsentNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.41 | ipmiEventNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.42 | storageDomainQuotaNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.43 | yodaAgentUnhealthyNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.44 | searchIndexManualMigrationNeededNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.45 | searchIndexMigrationFinishedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.46 | searchIndexMigrationTriggeredNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.47 | searchIndexMigrationBacklogNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.48 | vMOptimizedXFSVolumeIndexingSkippedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.49 | vMOptimizedNTFSVolumeIndexingSkippedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.50 | aVThreatFoundNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.51 | corruptFileSystemNotIndexedNotif | 0 | 0 | |
| 1.3.6.1.4.1.47421.0.52 | indexingPausedNotif | 0 | 0 |