FRM220- protection card Working On Primary Path LED: 0:off 1:on
Sources for this description
CTC Union MIB copies (Observium Community)
OID reference
1.3.6.1.4.1.4756.20.391.20.1.13
FRM220- protection card Working On Primary Path LED: 0:off 1:on
Identification
{1 3 6 1 4 1 4756 20 391 20 1 13}
| Value | Name |
|---|---|
| 0 | off |
| 1 | on |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In CTC-FRM220-MIB, the row index consists of these components in order:
protectionChassisIndex (INTEGER): one numeric subidentifier for the non-negative value.protectionSlotIndex (INTEGER): one numeric subidentifier for the non-negative value.An instance has the form .1.3.6.1.4.1.4756.20.391.20.1.13.<protectionChassisIndex>.<protectionSlotIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4756.20.391.20.1.13
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
protectionWorkingOnPrimaryPathLED OBJECT-TYPE
SYNTAX INTEGER{
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" FRM220- protection card Working On Primary Path LED:
0:off
1:on
"
::= { protectionEntry 13 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
FRM220- protection card Working On Primary Path LED: 0:off 1:on
CTC Union MIB copies (Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: protectionWorkingOnPrimaryPathLED
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"protectionWorkingOnPrimaryPathLED",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"0",
")",
",",
"on",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\" FRM220- protection card Working On Primary Path LED: 0:off 1:on \"",
"::=",
"{",
"protectionEntry",
"13",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
0
],
[
"on",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"FRM220- protection card Working On Primary Path LED: 0:off 1:on"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. CTC Union support.
Module: CTC-FRM220-MIB
See published definition above
{'RFC-1215': ['TRAP-TYPE'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'PhysAddress', 'TruthValue', 'RowStatus', 'TimeStamp', 'AutonomousType', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'Gauge32', 'Integer32', 'TimeTicks', 'mib-2', 'enterprises', 'IpAddress', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Registration