OID reference

f16G3RRate2

1.3.6.1.4.1.4756.20.490.20.1.55

Description

Local FRM220-16G-3R card Rate2(Dual Channel only): Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fiber Channel 16: 16GFC 17: 10GFC 18: 8GFC 19: 4GFC 20: 2GFC 21: 1GFC CPRI 24: x20 CPRI 25: x16 CPRI 26: x10 CPRI 27: x8 CPRI 28: x5 CPRI 29: x4 CPRI 30: x2 CPRI 3…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.4756.20.490.20.1 (f16G3REntry)
Node code
55
Node name
f16G3RRate2
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.4756.20.490.20.1.55
URN notation
urn:oid:1.3.6.1.4.1.4756.20.490.20.1.55
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 4756 20 490 20 1 55}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ctc(4756) frm220(20) f16G3RCards(490) f16G3RTable(20) f16G3REntry(1) f16G3RRate2(55)}
OID-IRI notation
  • /1/3/6/1/4/1/4756/20/490/20/1/55
  • /ISO/Identified-Organization/6/1/4/1/4756/20/490/20/1/55
  • /ISO/3/6/1/4/1/4756/20/490/20/1/55
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/4756/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/identified-organization/dod/internet/private/enterprise/ctc/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/identified-organization/dod/internet/private/enterprises/4756/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/identified-organization/dod/internet/private/enterprises/ctc/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/4756/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ctc/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/identified-organization/dod/internet/private/vendor-objects/4756/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/identified-organization/dod/internet/private/vendor-objects/ctc/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/org/dod/internet/private/enterprise/4756/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/org/dod/internet/private/enterprise/ctc/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/org/dod/internet/private/enterprises/4756/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/org/dod/internet/private/enterprises/ctc/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/org/dod/internet/private/ldap-enterprise/4756/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/org/dod/internet/private/ldap-enterprise/ctc/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/org/dod/internet/private/vendor-objects/4756/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • /iso/org/dod/internet/private/vendor-objects/ctc/frm220/f16G3RCards/f16G3RTable/f16G3REntry/f16G3RRate2
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current

Enumerated values

ValueName
0rate10GE
1rate1GE
2rate2500X
8oc192-STM64
9oc192-STM16
10oc24
11oc12-STM4
16rate16GFC
17rate10GFC
18rate8GFC
19rate4GFC
20rate2GFC
21rate1GFC
24x20CPRI
25x16CPRI
26x10CPRI
27x8CPRI
28x5CPRI
29x4CPRI
30x2CPRI
31x1CPRI
32x8OBSAI
33x4OBSAI
34x2OBSAI
35x1OBSAI
40rate10GE-OTU2e
41rate10GE-OTU1e
42stm64-OTU2
43stm16-OTU1
44rate10GFC-OTU2
48rate10GE-ODU2e
49rate10GE-ODU1e
50stm64-ODU2
51stm16-ODU1

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In CTC-FRM220-MIB, the row index consists of these components in order:

  1. f16G3RChassisIndex (INTEGER): one numeric subidentifier for the non-negative value.
  2. f16G3RSlotIndex (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.4756.20.490.20.1.55.<f16G3RChassisIndex>.<f16G3RSlotIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4756.20.490.20.1.55

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

f16G3RRate2  OBJECT-TYPE
			SYNTAX  INTEGER {
					    rate10GE(0),
						rate1GE(1),
						rate2500X(2),
						oc192-STM64(8),
						oc192-STM16(9),
						oc24(10),
						oc12-STM4(11),
						rate16GFC(16),
						rate10GFC(17),
						rate8GFC(18),
						rate4GFC(19),
						rate2GFC(20),
						rate1GFC(21),
						x20CPRI(24),
						x16CPRI(25),
						x10CPRI(26),
						x8CPRI(27),
						x5CPRI(28),
						x4CPRI(29),
						x2CPRI(30),
						x1CPRI(31),
						x8OBSAI(32),
						x4OBSAI(33),
						x2OBSAI(34),
						x1OBSAI(35),
						rate10GE-OTU2e(40),
						rate10GE-OTU1e(41),
						stm64-OTU2(42),
						stm16-OTU1(43),
						rate10GFC-OTU2(44),
						rate10GE-ODU2e(48),
						rate10GE-ODU1e(49), 
						stm64-ODU2(50),
						stm16-ODU1(51)
					}
			MAX-ACCESS  read-write
			STATUS  current
			DESCRIPTION
				"Local FRM220-16G-3R card Rate2(Dual Channel only):
				Ethernet
				0: 10GE
				1: 1GE
				2: 2500Base-X

				SONET/SDH
				8: OC-192/STM-64
				9: OC-48/STM-16
				10:OC-24
				11:OC-12/STM-4
				
				Fiber Channel 
				16: 16GFC
				17: 10GFC
				18: 8GFC
				19: 4GFC
				20: 2GFC
				21: 1GFC
				
				CPRI
				24: x20 CPRI
				25: x16 CPRI
				26: x10 CPRI
				27: x8  CPRI
				28: x5  CPRI
				29: x4  CPRI
				30: x2  CPRI
				31: x1  CPRI
				
				OBSAI
				32: x8 OBSAI
				33: x4 OBSAI
				34: x2 OBSAI
				35: x1 OBSAI
				
				OTU
				40: 10G LAN OTU2e 
				41: 10G LAN OTU1e
				42: STM-64 OTU2
				43: STM-16 OTU1
				44: 10G FC OTU2
				 
				ODU
				48: 10G LAN ODU2e
				49: 10G LAN ODU1e
				50: STM-64 ODU2
				51: STM-16 ODU1
			 "
			::= { f16G3REntry 55 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Local FRM220-16G-3R card Rate2(Dual Channel only): Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fiber Channel 16: 16GFC 17: 10GFC 18: 8GFC 19: 4GFC 20: 2GFC 21: 1GFC CPRI 24: x20 CPRI 25: x16 CPRI 26: x10 CPRI 27: x8 CPRI 28: x5 CPRI 29: x4 CPRI 30: x2 CPRI 31: x1 CPRI OBSAI 32: x8 OBSAI 33: x4 OBSAI 34: x2 OBSAI 35: x1 OBSAI OTU 40: 10G LAN OTU2e 41: 10G LAN OTU1e 42: STM-64 OTU2 43: STM-16 OTU1 44: 10G FC OTU2 ODU 48: 10G LAN ODU2e 49: 10G LAN ODU1e 50: STM-64 ODU2 51: STM-16 ODU1

Sources for this description

CTC Union MIB copies (Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1CTC Union MIB copies (Observium Community)1 record · 1 source

Description 1

f16G3RRate2 · currentCTC Union MIB copies (Observium Community)1 source

Status in source: current.

Names: f16G3RRate2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "f16G3RRate2",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "rate10GE",
    "(",
    "0",
    ")",
    ",",
    "rate1GE",
    "(",
    "1",
    ")",
    ",",
    "rate2500X",
    "(",
    "2",
    ")",
    ",",
    "oc192-STM64",
    "(",
    "8",
    ")",
    ",",
    "oc192-STM16",
    "(",
    "9",
    ")",
    ",",
    "oc24",
    "(",
    "10",
    ")",
    ",",
    "oc12-STM4",
    "(",
    "11",
    ")",
    ",",
    "rate16GFC",
    "(",
    "16",
    ")",
    ",",
    "rate10GFC",
    "(",
    "17",
    ")",
    ",",
    "rate8GFC",
    "(",
    "18",
    ")",
    ",",
    "rate4GFC",
    "(",
    "19",
    ")",
    ",",
    "rate2GFC",
    "(",
    "20",
    ")",
    ",",
    "rate1GFC",
    "(",
    "21",
    ")",
    ",",
    "x20CPRI",
    "(",
    "24",
    ")",
    ",",
    "x16CPRI",
    "(",
    "25",
    ")",
    ",",
    "x10CPRI",
    "(",
    "26",
    ")",
    ",",
    "x8CPRI",
    "(",
    "27",
    ")",
    ",",
    "x5CPRI",
    "(",
    "28",
    ")",
    ",",
    "x4CPRI",
    "(",
    "29",
    ")",
    ",",
    "x2CPRI",
    "(",
    "30",
    ")",
    ",",
    "x1CPRI",
    "(",
    "31",
    ")",
    ",",
    "x8OBSAI",
    "(",
    "32",
    ")",
    ",",
    "x4OBSAI",
    "(",
    "33",
    ")",
    ",",
    "x2OBSAI",
    "(",
    "34",
    ")",
    ",",
    "x1OBSAI",
    "(",
    "35",
    ")",
    ",",
    "rate10GE-OTU2e",
    "(",
    "40",
    ")",
    ",",
    "rate10GE-OTU1e",
    "(",
    "41",
    ")",
    ",",
    "stm64-OTU2",
    "(",
    "42",
    ")",
    ",",
    "stm16-OTU1",
    "(",
    "43",
    ")",
    ",",
    "rate10GFC-OTU2",
    "(",
    "44",
    ")",
    ",",
    "rate10GE-ODU2e",
    "(",
    "48",
    ")",
    ",",
    "rate10GE-ODU1e",
    "(",
    "49",
    ")",
    ",",
    "stm64-ODU2",
    "(",
    "50",
    ")",
    ",",
    "stm16-ODU1",
    "(",
    "51",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Local FRM220-16G-3R card Rate2(Dual Channel only): Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fiber Channel 16: 16GFC 17: 10GFC 18: 8GFC 19: 4GFC 20: 2GFC 21: 1GFC CPRI 24: x20 CPRI 25: x16 CPRI 26: x10 CPRI 27: x8 CPRI 28: x5 CPRI 29: x4 CPRI 30: x2 CPRI 31: x1 CPRI OBSAI 32: x8 OBSAI 33: x4 OBSAI 34: x2 OBSAI 35: x1 OBSAI OTU 40: 10G LAN OTU2e 41: 10G LAN OTU1e 42: STM-64 OTU2 43: STM-16 OTU1 44: 10G FC OTU2 ODU 48: 10G LAN ODU2e 49: 10G LAN ODU1e 50: STM-64 ODU2 51: STM-16 ODU1 \"",
    "::=",
    "{",
    "f16G3REntry",
    "55",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "rate10GE",
            0
          ],
          [
            "rate1GE",
            1
          ],
          [
            "rate2500X",
            2
          ],
          [
            "oc192-STM64",
            8
          ],
          [
            "oc192-STM16",
            9
          ],
          [
            "oc24",
            10
          ],
          [
            "oc12-STM4",
            11
          ],
          [
            "rate16GFC",
            16
          ],
          [
            "rate10GFC",
            17
          ],
          [
            "rate8GFC",
            18
          ],
          [
            "rate4GFC",
            19
          ],
          [
            "rate2GFC",
            20
          ],
          [
            "rate1GFC",
            21
          ],
          [
            "x20CPRI",
            24
          ],
          [
            "x16CPRI",
            25
          ],
          [
            "x10CPRI",
            26
          ],
          [
            "x8CPRI",
            27
          ],
          [
            "x5CPRI",
            28
          ],
          [
            "x4CPRI",
            29
          ],
          [
            "x2CPRI",
            30
          ],
          [
            "x1CPRI",
            31
          ],
          [
            "x8OBSAI",
            32
          ],
          [
            "x4OBSAI",
            33
          ],
          [
            "x2OBSAI",
            34
          ],
          [
            "x1OBSAI",
            35
          ],
          [
            "rate10GE-OTU2e",
            40
          ],
          [
            "rate10GE-OTU1e",
            41
          ],
          [
            "stm64-OTU2",
            42
          ],
          [
            "stm16-OTU1",
            43
          ],
          [
            "rate10GFC-OTU2",
            44
          ],
          [
            "rate10GE-ODU2e",
            48
          ],
          [
            "rate10GE-ODU1e",
            49
          ],
          [
            "stm64-ODU2",
            50
          ],
          [
            "stm16-ODU1",
            51
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Local FRM220-16G-3R card Rate2(Dual Channel only): Ethernet 0: 10GE 1: 1GE 2: 2500Base-X SONET/SDH 8: OC-192/STM-64 9: OC-48/STM-16 10:OC-24 11:OC-12/STM-4 Fiber Channel 16: 16GFC 17: 10GFC 18: 8GFC 19: 4GFC 20: 2GFC 21: 1GFC CPRI 24: x20 CPRI 25: x16 CPRI 26: x10 CPRI 27: x8 CPRI 28: x5 CPRI 29: x4 CPRI 30: x2 CPRI 31: x1 CPRI OBSAI 32: x8 OBSAI 33: x4 OBSAI 34: x2 OBSAI 35: x1 OBSAI OTU 40: 10G LAN OTU2e 41: 10G LAN OTU1e 42: STM-64 OTU2 43: STM-16 OTU1 44: 10G FC OTU2 ODU 48: 10G LAN ODU2e 49: 10G LAN ODU1e 50: STM-64 ODU2 51: STM-16 ODU1"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4756)

Fan Thomas

Siblings (137)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4756.20.490.20.1.51 f16G3RDataRate2Status00
1.3.6.1.4.1.4756.20.490.20.1.52 f16G3RProtocol100
1.3.6.1.4.1.4756.20.490.20.1.53 f16G3RRate100
1.3.6.1.4.1.4756.20.490.20.1.54 f16G3RProtocol200
1.3.6.1.4.1.4756.20.490.20.1.56 f16G3RChannel1Active00
1.3.6.1.4.1.4756.20.490.20.1.57 f16G3RChannel2Active00
1.3.6.1.4.1.4756.20.490.20.1.58 f16G3RFx1DDVendor00
1.3.6.1.4.1.4756.20.490.20.1.59 f16G3RFx1DDPartNo00
1.3.6.1.4.1.4756.20.490.20.1.60 f16G3RFx1DDVendorSN00
1.3.6.1.4.1.4756.20.490.20.1.61 f16G3RFx1DDFiberType00
1.3.6.1.4.1.4756.20.490.20.1.62 f16G3RFx1DDWaveLen00
1.3.6.1.4.1.4756.20.490.20.1.63 f16G3RFx1DDWaveLen200
1.3.6.1.4.1.4756.20.490.20.1.64 f16G3RFx1DDLinkLen00
1.3.6.1.4.1.4756.20.490.20.1.65 f16G3RFx1DDLenUnit00
1.3.6.1.4.1.4756.20.490.20.1.66 f16G3RFx1DDRxSens00
1.3.6.1.4.1.4756.20.490.20.1.67 f16G3RFx1DDTxPWR00
1.3.6.1.4.1.4756.20.490.20.1.68 f16G3RFx1DDRxPWR00
1.3.6.1.4.1.4756.20.490.20.1.69 f16G3RFx1RxPowerStatus00
1.3.6.1.4.1.4756.20.490.20.1.70 f16G3RFx1DDTemp00
1.3.6.1.4.1.4756.20.490.20.1.71 f16G3RFx1DDPWRMargin00
1.3.6.1.4.1.4756.20.490.20.1.72 f16G3RFx2DDVendor00
1.3.6.1.4.1.4756.20.490.20.1.73 f16G3RFx2DDPartNo00
1.3.6.1.4.1.4756.20.490.20.1.74 f16G3RFx2DDVendorSN00
1.3.6.1.4.1.4756.20.490.20.1.75 f16G3RFx2DDFiberType00
1.3.6.1.4.1.4756.20.490.20.1.76 f16G3RFx2DDWaveLen00
1.3.6.1.4.1.4756.20.490.20.1.77 f16G3RFx2DDWaveLen200
1.3.6.1.4.1.4756.20.490.20.1.78 f16G3RFx2DDLinkLen00
1.3.6.1.4.1.4756.20.490.20.1.79 f16G3RFx2DDLenUnit00
1.3.6.1.4.1.4756.20.490.20.1.80 f16G3RFx2DDRxSens00
1.3.6.1.4.1.4756.20.490.20.1.81 f16G3RFx2DDTxPWR00
1.3.6.1.4.1.4756.20.490.20.1.82 f16G3RFx2DDRxPWR00
1.3.6.1.4.1.4756.20.490.20.1.83 f16G3RFx2RxPowerStatus00
1.3.6.1.4.1.4756.20.490.20.1.84 f16G3RFx2DDTemp00
1.3.6.1.4.1.4756.20.490.20.1.85 f16G3RFx2DDPWRMargin00
1.3.6.1.4.1.4756.20.490.20.1.86 f16G3RFx3DDVendor00
1.3.6.1.4.1.4756.20.490.20.1.87 f16G3RFx3DDPartNo00
1.3.6.1.4.1.4756.20.490.20.1.88 f16G3RFx3DDVendorSN00
1.3.6.1.4.1.4756.20.490.20.1.89 f16G3RFx3DDFiberType00
1.3.6.1.4.1.4756.20.490.20.1.90 f16G3RFx3DDWaveLen00
1.3.6.1.4.1.4756.20.490.20.1.91 f16G3RFx3DDWaveLen200
1.3.6.1.4.1.4756.20.490.20.1.92 f16G3RFx3DDLinkLen00
1.3.6.1.4.1.4756.20.490.20.1.93 f16G3RFx3DDLenUnit00
1.3.6.1.4.1.4756.20.490.20.1.94 f16G3RFx3DDRxSens00
1.3.6.1.4.1.4756.20.490.20.1.95 f16G3RFx3DDTxPWR00
1.3.6.1.4.1.4756.20.490.20.1.96 f16G3RFx3DDRxPWR00
1.3.6.1.4.1.4756.20.490.20.1.97 f16G3RFx3RxPowerStatus00
1.3.6.1.4.1.4756.20.490.20.1.98 f16G3RFx3DDTemp00
1.3.6.1.4.1.4756.20.490.20.1.99 f16G3RFx3DDPWRMargin00
1.3.6.1.4.1.4756.20.490.20.1.100 f16G3RFx4DDVendor00
1.3.6.1.4.1.4756.20.490.20.1.101 f16G3RFx4DDPartNo00