Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"oab15Alarm",
"OBJECT-TYPE",
"SYNTAX",
"BITS",
"{",
"pump-drive-current-is-over-limit",
"(",
"0",
")",
",",
"output-power-is-less-than-setting-output-power",
"(",
"1",
")",
",",
"output-power-is-over-the-setting-output-power",
"(",
"2",
")",
",",
"ld-power-is-less-than-5mW-of-setting-pump-power",
"(",
"3",
")",
",",
"temperature-of-the-module-is-over-65-degree-C",
"(",
"4",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Local FRM220 OAB15 Alarm: 0:Pump drive current is over limit. 1:Output power is less than setting output power(< 1dB) 2:Output power is over the setting output power(> 1dB) 3:LD power is less than 5mW of setting pump power 4:Temperature of the module is over 65 degree C\"",
"::=",
"{",
"oab15Entry",
"23",
"}"
],
"syntax_tree": [
[
"BITS",
[
[
"pump-drive-current-is-over-limit",
0
],
[
"output-power-is-less-than-setting-output-power",
1
],
[
"output-power-is-over-the-setting-output-power",
2
],
[
"ld-power-is-less-than-5mW-of-setting-pump-power",
3
],
[
"temperature-of-the-module-is-over-65-degree-C",
4
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Local FRM220 OAB15 Alarm: 0:Pump drive current is over limit. 1:Output power is less than setting output power(< 1dB) 2:Output power is over the setting output power(> 1dB) 3:LD power is less than 5mW of setting pump power 4:Temperature of the module is over 65 degree C"
],
null,
null,
null,
null
]
}