Status of circuit breaker in power strip. 0=off 1=on.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4779.1.3.5.2.1.16
Status of circuit breaker in power strip. 0=off 1=on.
Identification
{1 3 6 1 4 1 4779 1 3 5 2 1 16}
| Value | Name |
|---|---|
| 0 | off |
| 1 | on |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In Baytech-MIB-401-4, the row index sBTAModulesRPCIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.4779.1.3.5.2.1.16.<sBTAModulesRPCIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4779.1.3.5.2.1.16
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sBTAModulesRPCCircuitBreaker OBJECT-TYPE
SYNTAX INTEGER {
off (0),
on (1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of circuit breaker in power strip. 0=off 1=on."
::= { sBTAModulesRPCEntry 16 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Status of circuit breaker in power strip. 0=off 1=on.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: sBTAModulesRPCCircuitBreaker
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sBTAModulesRPCCircuitBreaker",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"0",
")",
",",
"on",
"(",
"1",
")",
"}",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Status of circuit breaker in power strip. 0=off 1=on.\"",
"::=",
"{",
"sBTAModulesRPCEntry",
"16",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
0
],
[
"on",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Status of circuit breaker in power strip. 0=off 1=on."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: Baytech-MIB-401-4
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: Baytech-MIB-403-1
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4779.1.3.5.2.1.1 | sBTAModulesRPCIndex | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.2 | sBTAModulesRPCName | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.3 | sBTAModulesRPCFirmwareVersion | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.4 | sBTAModulesRPCCurrent | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.5 | sBTAModulesRPCMaxCurrent | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.6 | sBTAModulesRPCVoltage | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.7 | sBTAModulesRPCPower | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.8 | sBTAModulesRPCTemperature | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.9 | sBTAModulesRPCRebootTimeout | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.10 | sBTAModulesRPCAllOutletsCmd | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.11 | sBTAModulesRPCAllOutletsStatus | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.12 | sBTAModulesRPCCurrentAlarmThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.13 | sBTAModulesRPCOverVoltageThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.14 | sBTAModulesRPCUnderVoltageThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.15 | sBTAModulesRPCNumberOfOutlets | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.17 | sBTAModulesRPCOverTempThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.18 | sBTAModulesRPCUnitVA | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.19 | sBTAModulesRPCNumberOfBreakers | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.20 | sBTAModulesRPCLowCurrentThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.21 | sBTAModulesRPCVoltageSource | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.22 | sBTAModulesRPCSourceSwitchCount | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.23 | sBTAModulesRPCNumberOfSensors | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.3.5.2.1.24 | sBTAModulesRPCType | 0 | 0 |