Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4779.1.4.4.1.7
Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.
Identification
{1 3 6 1 4 1 4779 1 4 4 1 7}
| Value | Name |
|---|---|
| 1 | terminate |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In Baytech-MIB-401-4, the row index sBTAControlUserIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.4779.1.4.4.1.7.<sBTAControlUserIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4779.1.4.4.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sBTAControlUserTerminateUser OBJECT-TYPE
SYNTAX INTEGER {
terminate (1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Settings this OID to anything but 0 will terminate (log out) the user.
A get of this OID will return 0."
::= { sBTAControlUserEntry 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: sBTAControlUserTerminateUser
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sBTAControlUserTerminateUser",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"terminate",
"(",
"1",
")",
"}",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0.\"",
"::=",
"{",
"sBTAControlUserEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"terminate",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Settings this OID to anything but 0 will terminate (log out) the user. A get of this OID will return 0."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: Baytech-MIB-401-4
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: Baytech-MIB-403-1
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4779.1.4.4.1.1 | sBTAControlUserIndex | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.4.4.1.2 | sBTAControlUserName | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.4.4.1.3 | sBTAControlUserAddress | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.4.4.1.4 | sBTAControlUserConnection | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.4.4.1.5 | sBTAControlUserConnModule | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.4.4.1.6 | sBTAControlUserConnPort | 0 | 0 |