State change environmental sensor (ex: contact) trap enable.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4779.1.6.7
State change environmental sensor (ex: contact) trap enable.
Identification
{1 3 6 1 4 1 4779 1 6 7}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4779.1.6.7.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
sBTAEnvironmentalAllSensorsStateTrapEnable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"State change environmental sensor (ex: contact) trap enable."
::= { sBTAEnvironmental 7 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
State change environmental sensor (ex: contact) trap enable.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: sBTAEnvironmentalAllSensorsStateTrapEnable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sBTAEnvironmentalAllSensorsStateTrapEnable",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"State change environmental sensor (ex: contact) trap enable.\"",
"::=",
"{",
"sBTAEnvironmental",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"State change environmental sensor (ex: contact) trap enable."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: Baytech-MIB-401-4
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: Baytech-MIB-403-1
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4779.1.6.1 | sBTAModulesEnvironmentalObjectsTable | 1 | 13 | |
| 1.3.6.1.4.1.4779.1.6.2 | sRPCEnvironmentalObjectsTable | 1 | 14 | |
| 1.3.6.1.4.1.4779.1.6.3 | sBTAEnvironmentalAllTemperatureSensorsHiThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.4 | sBTAEnvironmentalAllTemperatureSensorsLoThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.5 | sBTAEnvironmentalAllTemperatureSensorsHiThresholdTrapEnable | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.6 | sBTAEnvironmentalAllTemperatureSensorsLoThresholdTrapEnable | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.8 | sBTAEnvironmentalAllHumiditySensorsHiThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.9 | sBTAEnvironmentalAllHumiditySensorsLoThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.10 | sBTAEnvironmentalAllHumiditySensorsHiThresholdTrapEnable | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.11 | sBTAEnvironmentalAllHumiditySensorsLoThresholdTrapEnable | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.12 | sBTAEnvironmentalAllAirflowSensorsHiThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.13 | sBTAEnvironmentalAllAirflowSensorsLoThreshold | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.14 | sBTAEnvironmentalAllAirflowSensorsHiThresholdTrapEnable | 0 | 0 | |
| 1.3.6.1.4.1.4779.1.6.15 | sBTAEnvironmentalAllAirflowSensorsLoThresholdTrapEnable | 0 | 0 |