Status in source: unspecified.
Names: chipAboveThreshold
Technical details
{
"smi_kind": "TRAP-TYPE",
"definition": [
"chipAboveThreshold",
"TRAP-TYPE",
"ENTERPRISE",
"chipcom",
"DESCRIPTION",
"\"When sent for an entry in olThreshTable: A chipAboveThreshold trap indicates that a variable that is being thresholded as specified by an entry in olThreshTable has exceeded its threshold. Another chipAboveThreshold trap will not be sent until olThreshCurrentValue drops below olThreshValue and then again exceeds it. The following variables are in the varBind list: olThreshIndex olThreshDescription olThreshStatCategory olThreshStatType olThreshStatNetID olThreshStatSlotIndex olThreshStatPortIndex olThreshStatStationAddr olThreshObjectIdentifier olThreshInterval olThreshCondition olThreshCurrentValue olThreshValue olThreshActionData olThreshActionPriority Notes: olThreshStatNetID is included only if olThreshStatCategory is network(2) or station(4). olThreshStatSlotIndex and olThreshStatPortIndex are included only if olThreshStatCategory is port(3). olThreshStatStationAddr is included only if olThreshStatCategory is station(4). olThreshObjectIdentifier is included only if olThreshStatCategory is other(1). Otherwise: A chipAboveThreshold trap indicates that a Counter or Gauge variable has exceeded its threshold. The variable which is above its threshold is the only variable in the varBind list. Its value is taken at the time the threshold calculation is performed and therefore may be greater than the actual threshold value. Another above threshold trap will not be sent until a below threshold trap is sent.\"",
"::=",
"14"
],
"syntax_tree": [
[
"objectIdentifier",
[
"chipcom"
]
],
[],
[
"DESCRIPTION",
"When sent for an entry in olThreshTable: A chipAboveThreshold trap indicates that a variable that is being thresholded as specified by an entry in olThreshTable has exceeded its threshold. Another chipAboveThreshold trap will not be sent until olThreshCurrentValue drops below olThreshValue and then again exceeds it. The following variables are in the varBind list: olThreshIndex olThreshDescription olThreshStatCategory olThreshStatType olThreshStatNetID olThreshStatSlotIndex olThreshStatPortIndex olThreshStatStationAddr olThreshObjectIdentifier olThreshInterval olThreshCondition olThreshCurrentValue olThreshValue olThreshActionData olThreshActionPriority Notes: olThreshStatNetID is included only if olThreshStatCategory is network(2) or station(4). olThreshStatSlotIndex and olThreshStatPortIndex are included only if olThreshStatCategory is port(3). olThreshStatStationAddr is included only if olThreshStatCategory is station(4). olThreshObjectIdentifier is included only if olThreshStatCategory is other(1). Otherwise: A chipAboveThreshold trap indicates that a Counter or Gauge variable has exceeded its threshold. The variable which is above its threshold is the only variable in the varBind list. Its value is taken at the time the threshold calculation is performed and therefore may be greater than the actual threshold value. Another above threshold trap will not be sent until a below threshold trap is sent."
],
null
]
}