Status in source: current.
Names: defaultMachineDetectionV21ModulationDetection
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"defaultMachineDetectionV21ModulationDetection",
"OBJECT-TYPE",
"SYNTAX",
"MxEnableState",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\" Default Enable/Disable V.21 Modulation Detection Enables fax V.21 modulation detection. * Enable: Upon recognition of the V.21 modulation tone, the unit switches the communication from voice mode to fax mode and the signal is transferred by using the preferred fax codec. * Disable: The V.21 modulation does not trigger a transition from voice to data and the signal is transferred in the voice channel. If a specific configuration is set in the SpecificMachineDetection.CedToneDetection parameter and the SpecificMachineDetection.EnableConfig parameter is set to 'Enable', then it overrides the current default configuration. \"",
"DEFVAL",
"{",
"enable",
"}",
"::=",
"{",
"machineDetectionGroup",
"102",
"}"
],
"syntax_tree": [
[
"row",
"MxEnableState"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Default Enable/Disable V.21 Modulation Detection Enables fax V.21 modulation detection. * Enable: Upon recognition of the V.21 modulation tone, the unit switches the communication from voice mode to fax mode and the signal is transferred by using the preferred fax codec. * Disable: The V.21 modulation does not trigger a transition from voice to data and the signal is transferred in the voice channel. If a specific configuration is set in the SpecificMachineDetection.CedToneDetection parameter and the SpecificMachineDetection.EnableConfig parameter is set to 'Enable', then it overrides the current default configuration."
],
null,
null,
null,
[
"DEFVAL",
"enable"
]
]
}