Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"clockReferenceSource",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"0",
".",
".",
"255",
")",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\" Clock Reference Source Indicates the preferred synchronisation source(s) to use for the internal clock. Refer to the ClockReferenceList parameter for a list of available clock references for the platform. When the value is empty, the platform will automatically choose the synchronisation source. When a source or a list of sources are specified, the internal clock is synchronised with the first source that offers a valid signal. The only exception is the SYNCIN port (not present on all platforms), which is always used when encountered in the list. Depending on the platform, two string separators may be used: * ',' (comma): List synchronisation sources, per priority (Sentinel and G7 platforms only). * ';' (semicolon): Adding a second synchronisation source (3xxx platform only) Examples: * For 44xx: 'Bri1' * For C7xx: 'BRI1, BRI2' * For 3xxx: 'Slot2/E1T1' * For 3xxx: 'Slot2/Bri0; Slot3/Bri2' * For Sentinel 400: 'Slot1/E1T1, Slot2/BRI1, Slot2/BRI2, SYNCIN' * For Sentinel 100 and G7: 'BRI1, BRI2, PRI1, PRI2, SYNCIN' * Any platform: '' \"",
"DEFVAL",
"{",
[
"literal",
"2222"
],
"}",
"::=",
"{",
"clockReference",
"200",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
0,
255
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Clock Reference Source Indicates the preferred synchronisation source(s) to use for the internal clock. Refer to the ClockReferenceList parameter for a list of available clock references for the platform. When the value is empty, the platform will automatically choose the synchronisation source. When a source or a list of sources are specified, the internal clock is synchronised with the first source that offers a valid signal. The only exception is the SYNCIN port (not present on all platforms), which is always used when encountered in the list. Depending on the platform, two string separators may be used: * ',' (comma): List synchronisation sources, per priority (Sentinel and G7 platforms only). * ';' (semicolon): Adding a second synchronisation source (3xxx platform only) Examples: * For 44xx: 'Bri1' * For C7xx: 'BRI1, BRI2' * For 3xxx: 'Slot2/E1T1' * For 3xxx: 'Slot2/Bri0; Slot3/Bri2' * For Sentinel 400: 'Slot1/E1T1, Slot2/BRI1, Slot2/BRI2, SYNCIN' * For Sentinel 100 and G7: 'BRI1, BRI2, PRI1, PRI2, SYNCIN' * Any platform: ''"
],
null,
null,
null,
[
"DEFVAL",
"\"\""
]
]
}