Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"configFileAutoUpdateTimeRange",
"OBJECT-TYPE",
"SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"0",
".",
".",
"24",
")",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The time of the day, based on sntpTimeZoneString, when the unit periodically fetches the configuration files in order to update the unit configuration. If a time range is specified, the unit will fetch the configuration files at a random time within the interval specified. The format should be one of the following: hh[:mm[:ss]] hh[:mm[:ss]] - hh[:mm[:ss]] Where: hh: Hours. mm: Minutes. ss: Seconds. The configuration files are fetched at the first occurrence of this value and thereafter with a period defined by configFileAutoUpdatePeriod. Let's say for instance the automatic unit configuration update is set with the time of day at 14h00 and the update period at every 2 days. If the automatic update is enabled before 14h00, the first update will take place the same day at 14h00, then the second update two days later at the same hour, and so on. If the time range is set to '14:00 - 15:00' and the automatic unit configuration update is enabled within those hours, the first update will take place the following day. This means that a range of '00:00:00 - 23:59:59' will always take place the next day. Note that the SNTP server needs to be enabled (see sntpEnable). Modification to this setting resets the update timer. It only applies when configFileAutoUpdateTimeUnit is set to 'days'.\"",
"DEFVAL",
"{",
[
"literal",
"2222"
],
"}",
"::=",
"{",
"configFileAutomaticUpdate",
"300",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"OCTET STRING",
[
"octetStringSubType",
[
[
0,
24
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The time of the day, based on sntpTimeZoneString, when the unit periodically fetches the configuration files in order to update the unit configuration. If a time range is specified, the unit will fetch the configuration files at a random time within the interval specified. The format should be one of the following: hh[:mm[:ss]] hh[:mm[:ss]] - hh[:mm[:ss]] Where: hh: Hours. mm: Minutes. ss: Seconds. The configuration files are fetched at the first occurrence of this value and thereafter with a period defined by configFileAutoUpdatePeriod. Let's say for instance the automatic unit configuration update is set with the time of day at 14h00 and the update period at every 2 days. If the automatic update is enabled before 14h00, the first update will take place the same day at 14h00, then the second update two days later at the same hour, and so on. If the time range is set to '14:00 - 15:00' and the automatic unit configuration update is enabled within those hours, the first update will take place the following day. This means that a range of '00:00:00 - 23:59:59' will always take place the next day. Note that the SNTP server needs to be enabled (see sntpEnable). Modification to this setting resets the update timer. It only applies when configFileAutoUpdateTimeUnit is set to 'days'."
],
null,
null,
null,
[
"DEFVAL",
"\"\""
]
]
}