Status in source: current.
Names: dataIfCedFaxToneEnable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"dataIfCedFaxToneEnable",
"OBJECT-TYPE",
"SYNTAX",
"MxEnableState",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Defines the behaviour of the unit upon reception of a CED fax tone from the network. enable: Upon reception of a CED tone following a sent CNG tone, the unit switches the communication from voice mode to fax mode and the CED is transferred by using the preferred fax codec. disable: The CED tone does not trigger a transition from voice to data and the CED is transferred in the voice channel. This configuration has no effect if the dataIfCngToneDetectionEnable variable is set to 'Enable'.\"",
"DEFVAL",
"{",
"disable",
"}",
"::=",
"{",
"dataIfEntry",
"100",
"}"
],
"syntax_tree": [
[
"row",
"MxEnableState"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Defines the behaviour of the unit upon reception of a CED fax tone from the network. enable: Upon reception of a CED tone following a sent CNG tone, the unit switches the communication from voice mode to fax mode and the CED is transferred by using the preferred fax codec. disable: The CED tone does not trigger a transition from voice to data and the CED is transferred in the voice channel. This configuration has no effect if the dataIfCngToneDetectionEnable variable is set to 'Enable'."
],
null,
null,
null,
[
"DEFVAL",
"disable"
]
]
}