Status in source: current.
Names: rdnCableFftConfigSpinLock
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rdnCableFftConfigSpinLock",
"OBJECT-TYPE",
"SYNTAX",
"TestAndIncr",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is used to initiate FFT measurement, and identify the current invocation an FFT measurement, for interface that is currently selected by rdnCableFftConfigIfIndex. This object is applicable to CMTS 2x8 cards, and to BSR2000. It is recommended that a management application will first read this object, then perform a set to the current value. This set may occur in the same set request as other sets. It is recommended that a management application will first read this object, then perform a set to the current value. This set may occur in the same set request as other sets. This object should be read again, and should return the previous value + 1, indicating the results are valid and the configuration has not changed. Else, another management station has initiated another measurement (following this procedure). 1. Get this object and store in configNum 2. Set any desired configuration objects 3. Set this object to configNum (Note: 2 & 3 can be done in the same set request) 4. If step 3 fails, then another management station has already set this object. 5. After short delay, get requested data from rdnCableFftResultTable. 6. Get this object and compare with configNum + 1 7. If step 6 yields the same value, the data retrieved in step 5 is valid. The use of rdnCableFftConfigSpinLock is to avoid conflicts with another SNMP command responder application which may also be acting on the rdnCableFftConfigObjects. Setting this object does not provide exclusive access. Other managers will still be able to modify these objects.\"",
"REFERENCE",
"\"RFC 2579, TestAndIncr\"",
"::=",
"{",
"rdnCableFftConfigObjects",
"2",
"}"
],
"syntax_tree": [
[
"row",
"TestAndIncr"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is used to initiate FFT measurement, and identify the current invocation an FFT measurement, for interface that is currently selected by rdnCableFftConfigIfIndex. This object is applicable to CMTS 2x8 cards, and to BSR2000. It is recommended that a management application will first read this object, then perform a set to the current value. This set may occur in the same set request as other sets. It is recommended that a management application will first read this object, then perform a set to the current value. This set may occur in the same set request as other sets. This object should be read again, and should return the previous value + 1, indicating the results are valid and the configuration has not changed. Else, another management station has initiated another measurement (following this procedure). 1. Get this object and store in configNum 2. Set any desired configuration objects 3. Set this object to configNum (Note: 2 & 3 can be done in the same set request) 4. If step 3 fails, then another management station has already set this object. 5. After short delay, get requested data from rdnCableFftResultTable. 6. Get this object and compare with configNum + 1 7. If step 6 yields the same value, the data retrieved in step 5 is valid. The use of rdnCableFftConfigSpinLock is to avoid conflicts with another SNMP command responder application which may also be acting on the rdnCableFftConfigObjects. Setting this object does not provide exclusive access. Other managers will still be able to modify these objects."
],
[
"REFERENCE",
"RFC 2579, TestAndIncr"
],
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: RDN-CABLE-SPECTRUM-GROUP-MIB
See published definition above
Module imports
{'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['DisplayString', 'RowStatus', 'DateAndTime', 'TEXTUAL-CONVENTION', 'TruthValue', 'TestAndIncr', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'IpAddress', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'docsIfUpChannelFrequency', 'docsIfUpChannelWidth', 'docsIfUpChannelModulationProfile'], 'RDN-CHASSIS-MIB': ['rdnSlotNumber', 'rdnCardIfSlotNumber', 'rdnCardIfPortNumber'], 'INET-ADDRESS-MIB': ['InetAddressIPv4', 'InetAddressIPv6'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'RDN-CABLE-SPECTRUM-MIB': ['rdnCableSpectrumObjects']}
· Download RDN-CABLE-SPECTRUM-GROUP-MIB