Maximum percentage of upstream resources that may be used by both normal and emergency telephony services.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4998.1.1.115.1.1.18
Maximum percentage of upstream resources that may be used by both normal and emergency telephony services.
Identification
{1 3 6 1 4 1 4998 1 1 115 1 1 18}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4998.1.1.115.1.1.18.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cadPCUpTotalAllowedUsage OBJECT-TYPE
SYNTAX INTEGER (0..100)
UNITS "percent"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum percentage of upstream resources that may be
used by both normal and emergency telephony services."
REFERENCE "'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
DEFVAL { 70 }
::= { cadPCMibBase 18 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Maximum percentage of upstream resources that may be used by both normal and emergency telephony services.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cadPCUpTotalAllowedUsage
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cadPCUpTotalAllowedUsage",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"100",
")",
"UNITS",
[
"literal",
"2270657263656e7422"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Maximum percentage of upstream resources that may be used by both normal and emergency telephony services.\"",
"REFERENCE",
"\"'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2\"",
"DEFVAL",
"{",
"70",
"}",
"::=",
"{",
"cadPCMibBase",
"18",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
100
]
]
]
],
[
"UNITS",
"percent"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Maximum percentage of upstream resources that may be used by both normal and emergency telephony services."
],
[
"REFERENCE",
"'Cadant CMTS Requirements for PacketCable' requirement 3.3.3.0.2"
],
null,
null,
[
"DEFVAL",
70
]
]
}Vendor MIB copy from the Observium Community archive.
Module: CADANT-CMTS-PACKETCABLE-MIB
See published definition above
{'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'CADANT-TC': ['CardId', 'AdminState'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'TruthValue', 'DisplayString', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'IpAddress', 'Unsigned32', 'Counter32'], 'DOCS-QOS3-MIB': ['IfDirection'], 'CADANT-PRODUCTS-MIB': ['cadCable'], 'CADANT-CMTS-PROCESS-MIB': ['cadOvSysCpuStatus'], 'CADANT-CMTS-DOWNCHANNEL-MIB': ['cadIfCmtsCardNumber']}Related source files and packages:
Registration