Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cadIfDownChannelPower",
"OBJECT-TYPE",
"SYNTAX",
"TenthdBmV",
"(",
"0",
"|",
"250",
".",
".",
"600",
")",
"UNITS",
[
"literal",
"2264426d5622"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The CMTS operational transmit power. If this CMTS interface does not support output power control then this object will return 0 and be treated as read-only. If the interface is down, this object either returns the configured value or the value of 0. See the reference for recommended and required power levels.\"",
"REFERENCE",
"\"DOCSIS Radio Frequency Interface Specification, Table 4-12 and Table 4-13.\"",
"DEFVAL",
"{",
"380",
"}",
"::=",
"{",
"cadIfDownstreamChannelEntry",
"6",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"TenthdBmV",
[
"integerSubType",
[
[
0
],
[
250,
600
]
]
]
],
[
"UNITS",
"dBmV"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The CMTS operational transmit power. If this CMTS interface does not support output power control then this object will return 0 and be treated as read-only. If the interface is down, this object either returns the configured value or the value of 0. See the reference for recommended and required power levels."
],
[
"REFERENCE",
"DOCSIS Radio Frequency Interface Specification, Table 4-12 and Table 4-13."
],
null,
null,
[
"DEFVAL",
380
]
]
}