Status in source: unspecified.
Technical details
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"cadTimeMib",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230313531303139303030305a22"
],
"ORGANIZATION",
"\"Arris International, Inc.\"",
"CONTACT-INFO",
"\"Arris Technical Support Postal: ARRIS Phone: +1 770 622 8530 E-Mail: support@arrisi.com\"",
"DESCRIPTION",
"\"This MIB contains objects for controlling and reporting on the various Time of Day Services in the Cadant C4 CMTS. These Time of Day services include the TOD protocol, the NTP protocol, and manual configuration.\"",
"REVISION",
[
"literal",
"223230313531303139303030305a22"
],
"DESCRIPTION",
"\"Changed the typos in the wording of the description of cadTZAbbrev.\"",
"REVISION",
[
"literal",
"223230313130323037303030305a22"
],
"DESCRIPTION",
"\"Changed the cadNtpSourceMaxPollDefault from 10 to 7 representing a change from 1024 seconds to 128 seconds.\"",
"REVISION",
[
"literal",
"223230303630333037303030305a22"
],
"DESCRIPTION",
"\"Changed the size of cadNtpAuthKeyValue from exact 16 to (1..16) character long.\"",
"REVISION",
[
"literal",
"223230303530373236303030305a22"
],
"DESCRIPTION",
"\"Added cadNtpAuthKeyTable. Removed cadNtpMaster objects.\"",
"REVISION",
[
"literal",
"223230303330393131303030305a22"
],
"DESCRIPTION",
"\"Changed ranged objects from Unsigned32 to Integer32\"",
"REVISION",
[
"literal",
"223230303330343239303030305a22"
],
"DESCRIPTION",
"\"Promoted cadTimeMib from cadExperimental.13 to cadSystem.2\"",
"REVISION",
[
"literal",
"223230303231303238303030305a22"
],
"DESCRIPTION",
"\"Removed manycastPeer(6) value from cadNtpSourceEntryType.\"",
"REVISION",
[
"literal",
"223230303231303233303030305a22"
],
"DESCRIPTION",
"\"created and Temporarily removed all master scalar objects.\"",
"::=",
"{",
"cadSystem",
"2",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"201510190000Z"
],
[
"ORGANIZATION",
"Arris International, Inc."
],
[
"CONTACT-INFO",
"Arris Technical Support Postal: ARRIS Phone: +1 770 622 8530 E-Mail: support@arrisi.com"
],
[
"DESCRIPTION",
"This MIB contains objects for controlling and reporting on the various Time of Day Services in the Cadant C4 CMTS. These Time of Day services include the TOD protocol, the NTP protocol, and manual configuration."
],
[
"Revisions",
[
[
"201510190000Z",
[
"DESCRIPTION",
"Changed the typos in the wording of the description of cadTZAbbrev."
]
],
[
"201102070000Z",
[
"DESCRIPTION",
"Changed the cadNtpSourceMaxPollDefault from 10 to 7 representing a change from 1024 seconds to 128 seconds."
]
],
[
"200603070000Z",
[
"DESCRIPTION",
"Changed the size of cadNtpAuthKeyValue from exact 16 to (1..16) character long."
]
],
[
"200507260000Z",
[
"DESCRIPTION",
"Added cadNtpAuthKeyTable. Removed cadNtpMaster objects."
]
],
[
"200309110000Z",
[
"DESCRIPTION",
"Changed ranged objects from Unsigned32 to Integer32"
]
],
[
"200304290000Z",
[
"DESCRIPTION",
"Promoted cadTimeMib from cadExperimental.13 to cadSystem.2"
]
],
[
"200210280000Z",
[
"DESCRIPTION",
"Removed manycastPeer(6) value from cadNtpSourceEntryType."
]
],
[
"200210230000Z",
[
"DESCRIPTION",
"created and Temporarily removed all master scalar objects."
]
]
]
]
]
}