Setting this value to true will reset the counts associated with load balancing. Reading this value will always return false.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4998.1.1.50.1.8.1
Setting this value to true will reset the counts associated with load balancing. Reading this value will always return false.
Identification
{1 3 6 1 4 1 4998 1 1 50 1 8 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cadLoadBalClearCounts OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value to true will reset the counts associated with
load balancing. Reading this value will always return false."
DEFVAL { false }
::= { cadLoadBalControlGroup 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Setting this value to true will reset the counts associated with load balancing. Reading this value will always return false.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cadLoadBalClearCounts
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cadLoadBalClearCounts",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Setting this value to true will reset the counts associated with load balancing. Reading this value will always return false.\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"cadLoadBalControlGroup",
"1",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Setting this value to true will reset the counts associated with load balancing. Reading this value will always return false."
],
null,
null,
null,
[
"DEFVAL",
"false"
]
]
}Vendor MIB copy from the Observium Community archive.
Module: CADANT-LOADBALANCING-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'CADANT-TC': ['CardId', 'OUIAddress'], 'SNMPv2-TC': ['RowStatus', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter32'], 'DOCS-IF3-MIB': ['IfDirection'], 'DOCS-LOADBAL3-MIB': ['docsLoadbal3BasicRuleEntry', 'docsLoadbal3ResGrpCfgId'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'CADANT-CMTS-MAC-MIB': ['cadIfCmtsCmStatusMacAddress'], 'CADANT-PRODUCTS-MIB': ['cadSchema']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4998.1.1.50.1.8.2 | cadLoadBalRCSControl | 0 | 0 | |
| 1.3.6.1.4.1.4998.1.1.50.1.8.3 | cadLoadBalTCSControl | 0 | 0 | |
| 1.3.6.1.4.1.4998.1.1.50.1.8.4 | cadLoadBalTCSMoveUsPrimaryControl | 0 | 0 | |
| 1.3.6.1.4.1.4998.1.1.50.1.8.5 | cadLoadBalDbcMoveUsPrimaryControl | 0 | 0 |