OID reference

acSysTimingE1LineBuildOut

1.3.6.1.4.1.5003.9.10.10.1.14.9

Description

Sets the transmission power between the timing module on the SAT and the E1 external reference clock (ohms). This parameter is only relevant for the Mediant 3000.This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM_External_MODE(1). One of the following values: E_75_OHM_with_high_return_loss(4),E_1…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.5003.9.10.10.1.14 (acSysTiming)
Node code
9
Node name
acSysTimingE1LineBuildOut
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.5003.9.10.10.1.14.9
URN notation
urn:oid:1.3.6.1.4.1.5003.9.10.10.1.14.9
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 5003 9 10 10 1 14 9}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) audioCodes(5003) acProducts(9) acBoardMibs(10) acSystem(10) acSystemConfiguration(1) acSysTiming(14) acSysTimingE1LineBuildOut(9)}
OID-IRI notation
  • /1/3/6/1/4/1/5003/9/10/10/1/14/9
  • /ISO/Identified-Organization/6/1/4/1/5003/9/10/10/1/14/9
  • /ISO/3/6/1/4/1/5003/9/10/10/1/14/9
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/5003/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/identified-organization/dod/internet/private/enterprise/audioCodes/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/identified-organization/dod/internet/private/enterprises/5003/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/identified-organization/dod/internet/private/enterprises/audioCodes/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/5003/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/audioCodes/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/identified-organization/dod/internet/private/vendor-objects/5003/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/identified-organization/dod/internet/private/vendor-objects/audioCodes/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/org/dod/internet/private/enterprise/5003/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/org/dod/internet/private/enterprise/audioCodes/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/org/dod/internet/private/enterprises/5003/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/org/dod/internet/private/enterprises/audioCodes/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/org/dod/internet/private/ldap-enterprise/5003/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/org/dod/internet/private/ldap-enterprise/audioCodes/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/org/dod/internet/private/vendor-objects/5003/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • /iso/org/dod/internet/private/vendor-objects/audioCodes/acProducts/acBoardMibs/acSystem/acSystemConfiguration/acSysTiming/acSysTimingE1LineBuildOut
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
obsolete

Enumerated values

ValueName
0tm75OhmNormal
1tm120OhmNormal
4tm75OhmHighReturnLoss
5tm120OhmHighReturnLoss
6tm75OhmNormalGappedClock
7tm120OhmNormalGappedClock

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.5003.9.10.10.1.14.9.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 3 distinct definitions; some records may not include a definition.

Show 3 published definitions

acSysTimingE1LineBuildOut · obsolete

acSysTimingE1LineBuildOut OBJECT-TYPE
       SYNTAX INTEGER {
                  tm75OhmNormal(0)
,
                  tm120OhmNormal(1)
,
                  tm75OhmHighReturnLoss(4)
,
                  tm120OhmHighReturnLoss(5)
,
                  tm75OhmNormalGappedClock(6)
,
                  tm120OhmNormalGappedClock(7)

                  }
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "Sets the transmission power between the timing module on the
SAT and the E1 external reference clock (ohms). This parameter
is only relevant for the Mediant 3000.This parameter is
enabled when bspTimingModuleCfgTimingMode is set to TM_External_MODE(1).

One of the following values: E_75_OHM_with_high_return_loss(4),E_120_OHM_with_high_return_loss(5),E_75_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(6),E_120_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(7),E_75_OHM_normal(0),E_120_OHM_normal(1).
Access: Online.
AC INI-Param: TME1LineBuildOut "
       ::= {acSysTiming 9}

acSysTimingE1LineBuildOut · obsolete

acSysTimingE1LineBuildOut OBJECT-TYPE
       SYNTAX INTEGER {
                  tm75OhmNormal(0)
,
                  tm120OhmNormal(1)
,
                  tm75OhmHighReturnLoss(4)
,
                  tm120OhmHighReturnLoss(5)
,
                  tm75OhmNormalGappedClock(6)
,
                  tm120OhmNormalGappedClock(7)

                  }
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "Sets the transmission power between the timing module on the
SAT and the E1 external reference clock (ohms). This parameter
is only relevant for the Mediant 3000.This parameter is
enabled when bspTimingModuleCfgTimingMode is set to TM_External_MODE(1).

One of the following values: E_75_OHM_with_high_return_loss(4),E_120_OHM_with_high_return_loss(5),E_75_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(6),E_120_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(7),E_75_OHM_normal(0),E_120_OHM_normal(1).
Access: Online.
AC INI-Param: TME1LineBuildOut "
       ::= {acSysTiming 9}

acSysTimingE1LineBuildOut · obsolete

acSysTimingE1LineBuildOut OBJECT-TYPE
       SYNTAX INTEGER {
                  tm75OhmNormal(0)
,
                  tm120OhmNormal(1)
,
                  tm75OhmHighReturnLoss(4)
,
                  tm120OhmHighReturnLoss(5)
,
                  tm75OhmNormalGappedClock(6)
,
                  tm120OhmNormalGappedClock(7)

                  }
       MAX-ACCESS read-write
       STATUS obsolete
       DESCRIPTION
           "Sets the transmission power between the timing module on the
SAT and the E1 external reference clock (ohms). This parameter
is only relevant for the Mediant 3000.This parameter is
enabled when bspTimingModuleCfgTimingMode is set to TM-External-MODE(1).

One of the following values: E-75-OHM-with-high-return-loss(4),E-120-OHM-with-high-return-loss(5),E-75-OHM-normal-PLUS-enable-transmit-and-receive-gapped-clock(6),E-120-OHM-normal-PLUS-enable-transmit-and-receive-gapped-clock(7),E-75-OHM-normal(0),E-120-OHM-normal(1).
Access: Online.
AC INI-Param: TME1LineBuildOut "
       ::= {acSysTiming 9}

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Sets the transmission power between the timing module on the SAT and the E1 external reference clock (ohms). This parameter is only relevant for the Mediant 3000.This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM_External_MODE(1). One of the following values: E_75_OHM_with_high_return_loss(4),E_120_OHM_with_high_return_loss(5),E_75_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(6),E_120_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(7),E_75_OHM_normal(0),E_120_OHM_normal(1). Access: Online. AC INI-Param: TME1LineBuildOut

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 2

Sets the transmission power between the timing module on the SAT and the E1 external reference clock (ohms). This parameter is only relevant for the Mediant 3000.This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM-External-MODE(1). One of the following values: E-75-OHM-with-high-return-loss(4),E-120-OHM-with-high-return-loss(5),E-75-OHM-normal-PLUS-enable-transmit-and-receive-gapped-clock(6),E-120-OHM-normal-PLUS-enable-transmit-and-receive-gapped-clock(7),E-75-OHM-normal(0),E-120-OHM-normal(1). Access: Online. AC INI-Param: TME1LineBuildOut

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

acSysTimingE1LineBuildOut · obsoleteMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: obsolete.

Names: acSysTimingE1LineBuildOut

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "acSysTimingE1LineBuildOut",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "tm75OhmNormal",
    "(",
    "0",
    ")",
    ",",
    "tm120OhmNormal",
    "(",
    "1",
    ")",
    ",",
    "tm75OhmHighReturnLoss",
    "(",
    "4",
    ")",
    ",",
    "tm120OhmHighReturnLoss",
    "(",
    "5",
    ")",
    ",",
    "tm75OhmNormalGappedClock",
    "(",
    "6",
    ")",
    ",",
    "tm120OhmNormalGappedClock",
    "(",
    "7",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "obsolete",
    "DESCRIPTION",
    "\"Sets the transmission power between the timing module on the SAT and the E1 external reference clock (ohms). This parameter is only relevant for the Mediant 3000.This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM_External_MODE(1). One of the following values: E_75_OHM_with_high_return_loss(4),E_120_OHM_with_high_return_loss(5),E_75_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(6),E_120_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(7),E_75_OHM_normal(0),E_120_OHM_normal(1). Access: Online. AC INI-Param: TME1LineBuildOut \"",
    "::=",
    "{",
    "acSysTiming",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "tm75OhmNormal",
            0
          ],
          [
            "tm120OhmNormal",
            1
          ],
          [
            "tm75OhmHighReturnLoss",
            4
          ],
          [
            "tm120OhmHighReturnLoss",
            5
          ],
          [
            "tm75OhmNormalGappedClock",
            6
          ],
          [
            "tm120OhmNormalGappedClock",
            7
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "obsolete"
    ],
    [
      "DESCRIPTION",
      "Sets the transmission power between the timing module on the SAT and the E1 external reference clock (ohms). This parameter is only relevant for the Mediant 3000.This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM_External_MODE(1). One of the following values: E_75_OHM_with_high_return_loss(4),E_120_OHM_with_high_return_loss(5),E_75_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(6),E_120_OHM_normal_PLUS_enable_transmit_and_receive_gapped_clock(7),E_75_OHM_normal(0),E_120_OHM_normal(1). Access: Online. AC INI-Param: TME1LineBuildOut"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies1 record · 2 sources

Description 2

acSysTimingE1LineBuildOut · obsoleteMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies2 sources

Status in source: obsolete.

Names: acSysTimingE1LineBuildOut

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "acSysTimingE1LineBuildOut",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "tm75OhmNormal",
    "(",
    "0",
    ")",
    ",",
    "tm120OhmNormal",
    "(",
    "1",
    ")",
    ",",
    "tm75OhmHighReturnLoss",
    "(",
    "4",
    ")",
    ",",
    "tm120OhmHighReturnLoss",
    "(",
    "5",
    ")",
    ",",
    "tm75OhmNormalGappedClock",
    "(",
    "6",
    ")",
    ",",
    "tm120OhmNormalGappedClock",
    "(",
    "7",
    ")",
    "}",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "obsolete",
    "DESCRIPTION",
    "\"Sets the transmission power between the timing module on the SAT and the E1 external reference clock (ohms). This parameter is only relevant for the Mediant 3000.This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM-External-MODE(1). One of the following values: E-75-OHM-with-high-return-loss(4),E-120-OHM-with-high-return-loss(5),E-75-OHM-normal-PLUS-enable-transmit-and-receive-gapped-clock(6),E-120-OHM-normal-PLUS-enable-transmit-and-receive-gapped-clock(7),E-75-OHM-normal(0),E-120-OHM-normal(1). Access: Online. AC INI-Param: TME1LineBuildOut \"",
    "::=",
    "{",
    "acSysTiming",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "tm75OhmNormal",
            0
          ],
          [
            "tm120OhmNormal",
            1
          ],
          [
            "tm75OhmHighReturnLoss",
            4
          ],
          [
            "tm120OhmHighReturnLoss",
            5
          ],
          [
            "tm75OhmNormalGappedClock",
            6
          ],
          [
            "tm120OhmNormalGappedClock",
            7
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "obsolete"
    ],
    [
      "DESCRIPTION",
      "Sets the transmission power between the timing module on the SAT and the E1 external reference clock (ohms). This parameter is only relevant for the Mediant 3000.This parameter is enabled when bspTimingModuleCfgTimingMode is set to TM-External-MODE(1). One of the following values: E-75-OHM-with-high-return-loss(4),E-120-OHM-with-high-return-loss(5),E-75-OHM-normal-PLUS-enable-transmit-and-receive-gapped-clock(6),E-120-OHM-normal-PLUS-enable-transmit-and-receive-gapped-clock(7),E-75-OHM-normal(0),E-120-OHM-normal(1). Access: Online. AC INI-Param: TME1LineBuildOut"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.5003)

Kudevitzki Oren

Siblings (9)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.5003.9.10.10.1.14.1 acSysTimingMode00
1.3.6.1.4.1.5003.9.10.10.1.14.2 acSysTimingValidationTime00
1.3.6.1.4.1.5003.9.10.10.1.14.3 acSysTimingClockToDeriveA00
1.3.6.1.4.1.5003.9.10.10.1.14.4 acSysTimingClockToDeriveB00
1.3.6.1.4.1.5003.9.10.10.1.14.5 acSysTimingExternalIFType00
1.3.6.1.4.1.5003.9.10.10.1.14.6 acSysTimingLoopBackRef100
1.3.6.1.4.1.5003.9.10.10.1.14.7 acSysTimingLoopBackRef200
1.3.6.1.4.1.5003.9.10.10.1.14.8 acSysTimingTransmitControl00
1.3.6.1.4.1.5003.9.10.10.1.14.10 acSysTimingT1LineBuildOut00