Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"acAnalogFxsMeteringType",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"mt12kHz",
"(",
"0",
")",
",",
"mt16kHz",
"(",
"1",
")",
",",
"mtPolarityReversal",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Sets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-Param: METERINGTYPE\"",
"::=",
"{",
"acAnalogFxs",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"mt12kHz",
0
],
[
"mt16kHz",
1
],
[
"mtPolarityReversal",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Sets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-Param: METERINGTYPE"
],
null,
null,
null,
null
]
}