hiscomMacControlFlushAll — Belden, GarrettCom and Hirschmann IT official standalone MIBs
Flush all dynamic learned Mac addresses. Set the value to 'true' to perform the action. Read will always return 'false'.
{1 3 6 1 4 1 51735 1 12 1 4 1}
Flush all dynamic learned Mac addresses. Set the value to 'true' to perform the action. Read will always return 'false'.
Status in source: current.
Names: hiscomMacControlFlushAll
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"hiscomMacControlFlushAll",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Flush all dynamic learned Mac addresses. Set the value to 'true' to perform the action. Read will always return 'false'.\"",
"::=",
"{",
"hiscomMacControl",
"1",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Flush all dynamic learned Mac addresses. Set the value to 'true' to perform the action. Read will always return 'false'."
],
null,
null,
null,
null
]
}Module: HISCOM-MAC-MIB
hiscomMacControlFlushAll OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flush all dynamic learned Mac addresses. Set the value to 'true' to
perform the action. Read will always return 'false'."
::= { hiscomMacControl 1 }{'HISCOM-TC': ['HISCOMInterfaceIndex', 'HISCOMPortList', 'HISCOMRowEditorState', 'HISCOMUnsigned8', 'HISCOMVlan'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'MacAddress', 'TruthValue'], 'HISCOM-SMI': ['hiscomSwitchMgmt'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T12:48:04.692334+00:00.