Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - Unlock the port, 0 - do nothing.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.5205.2.16.1.10.2.1.4
Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - Unlock the port, 0 - do nothing.
Identification
{1 3 6 1 4 1 5205 2 16 1 10 2 1 4}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In RUBYTECH-ES2126-MIB, the row index es2126LoopDetectedfIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.5205.2.16.1.10.2.1.4.<es2126LoopDetectedfIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index variants: es2126LoopDetectedfIndex; feSW26LoopDetectedfIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.5205.2.16.1.10.2.1.4
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
es2126LoopDetectedResumed OBJECT-TYPE
SYNTAX INTEGER(0|1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unlock the port which is locked due to loop condition. Get this OID always return zero.
1 - Unlock the port,
0 - do nothing."
::= { es2126LoopDetectedEntry 4 }feSW26LoopDetectedResumed OBJECT-TYPE
SYNTAX INTEGER(0|1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unlock the port which is locked due to loop condition. Get this OID always return zero.
1 - Unlock the port,
0 - do nothing."
::= { feSW26LoopDetectedEntry 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - Unlock the port, 0 - do nothing.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: es2126LoopDetectedResumed
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"es2126LoopDetectedResumed",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
"|",
"1",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - Unlock the port, 0 - do nothing.\"",
"::=",
"{",
"es2126LoopDetectedEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0
],
[
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - Unlock the port, 0 - do nothing."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: RUBYTECH-ES2126-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Status in source: current.
Names: feSW26LoopDetectedResumed
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"feSW26LoopDetectedResumed",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
"|",
"1",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - Unlock the port, 0 - do nothing.\"",
"::=",
"{",
"feSW26LoopDetectedEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0
],
[
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - Unlock the port, 0 - do nothing."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: PRIVATE-FESW-26-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5205.2.16.1.10.2.1.1 | es2126LoopDetectedfIndex, feSW26LoopDetectedfIndex | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.16.1.10.2.1.2 | es2126LoopDetectedStateEbl, feSW26LoopDetectedStateEbl | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.16.1.10.2.1.3 | es2126LoopDetectedCurrentStatus, feSW26LoopDetectedCurrentStatus | 0 | 0 |