The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.5205.2.34.1.23.2.1.3
The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto
Identification
{1 3 6 1 4 1 5205 2 34 1 23 2 1 3}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In RUBYTECH-FGS2924R-MIB, the row index fgs2924rDot1XPort is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.5205.2.34.1.23.2.1.3.<fgs2924rDot1XPort>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index variants: fgs2924rDot1XPort; sw0657841Dot1XPort; sw0657851Dot1XPort.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.5205.2.34.1.23.2.1.3
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 3 distinct definitions; some records may not include a definition.
sw0657851Dot1XPortControl OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current value of the controlled Port
control parameter of the Port.
0 : ForceUnauthorized,
1 : ForceAuthorized,
2 : Auto
"
::= { sw0657851Dot1XPortConfEntry 3 }fgs2924rDot1XPortControl OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current value of the controlled Port
control parameter of the Port.
0 : ForceUnauthorized,
1 : ForceAuthorized,
2 : Auto
"
::= { fgs2924rDot1XPortConfEntry 3 }sw0657841Dot1XPortControl OBJECT-TYPE
SYNTAX INTEGER(0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current value of the controlled Port
control parameter of the Port.
0 : ForceUnauthorized,
1 : ForceAuthorized,
2 : Auto
"
::= { sw0657841Dot1XPortConfEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sw0657851Dot1XPortControl
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sw0657851Dot1XPortControl",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"2",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto \"",
"::=",
"{",
"sw0657851Dot1XPortConfEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: SIGNAMAX-SW0657851-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'BRIDGE-MIB': ['MacAddress'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Status in source: current.
Names: fgs2924rDot1XPortControl
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fgs2924rDot1XPortControl",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"2",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto \"",
"::=",
"{",
"fgs2924rDot1XPortConfEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: RUBYTECH-FGS2924R-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'BRIDGE-MIB': ['MacAddress'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Status in source: current.
Names: sw0657841Dot1XPortControl
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sw0657841Dot1XPortControl",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"(",
"0",
".",
".",
"2",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto \"",
"::=",
"{",
"sw0657841Dot1XPortConfEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"integerSubType",
[
[
0,
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The current value of the controlled Port control parameter of the Port. 0 : ForceUnauthorized, 1 : ForceAuthorized, 2 : Auto"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: INTELEK-SW0657841-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'BRIDGE-MIB': ['MacAddress'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32', 'IpAddress'], 'RFC1213-MIB': ['ifIndex'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.1 | fgs2924rDot1XPort, sw0657841Dot1XPort, sw0657851Dot1XPort | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.2 | fgs2924rDot1XPortMode, sw0657841Dot1XPortMode, sw0657851Dot1XPortMode | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.4 | fgs2924rDot1XPortreAuthMax, sw0657841Dot1XPortreAuthMax, sw0657851Dot1XPortreAuthMax | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.5 | fgs2924rDot1XPorttxPeriod, sw0657841Dot1XPorttxPeriod, sw0657851Dot1XPorttxPeriod | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.6 | fgs2924rDot1XPortquietPeriod, sw0657841Dot1XPortquietPeriod, sw0657851Dot1XPortquietPeriod | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.7 | fgs2924rDot1XPortreAuthEnabled, sw0657841Dot1XPortreAuthEnabled, sw0657851Dot1XPortreAuthEnabled | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.8 | fgs2924rDot1XPortreAuthPeriod, sw0657841Dot1XPortreAuthPeriod, sw0657851Dot1XPortreAuthPeriod | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.9 | fgs2924rDot1XPortmaxReq, sw0657841Dot1XPortmaxReq, sw0657851Dot1XPortmaxReq | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.10 | fgs2924rDot1XPortsuppTimeout, sw0657841Dot1XPortsuppTimeout, sw0657851Dot1XPortsuppTimeout | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.11 | fgs2924rDot1XPortserverTimeout, sw0657841Dot1XPortserverTimeout, sw0657851Dot1XPortserverTimeout | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.12 | fgs2924rDot1XPortVlanAssignment | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.13 | fgs2924rDot1XPortGuestVlan | 0 | 0 | |
| 1.3.6.1.4.1.5205.2.34.1.23.2.1.14 | fgs2924rDot1XPortAuthFailedVlan | 0 | 0 |