aAlarmEventNotify — FS.COM MIB copies (LibreNMS/Observium Community)
This trap will be generated when system fault is detected or released. ie. unit-out, tca, etc.
{1 3 6 1 4 1 52642 1 91 100 1}
This trap will be generated when system fault is detected or released. ie. unit-out, tca, etc.
Status in source: current.
Names: aAlarmEventNotify
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"aAlarmEventNotify",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"alarmHistoryLogSeq",
",",
"alarmHistoryLogType",
",",
"alarmHistoryLogObject",
",",
"alarmHistoryLogSeverity",
",",
"alarmHistoryLogServiceAffect",
",",
"alarmHistoryLogAddInfo",
",",
"alarmHistoryLogOccurTime",
",",
"alarmHistoryLogReleaseTime",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"This trap will be generated when system fault is detected or released. ie. unit-out, tca, etc.\"",
"::=",
"{",
"alarmTrap",
"1",
"}"
],
"syntax_tree": [
[
"Objects",
[
"alarmHistoryLogSeq",
"alarmHistoryLogType",
"alarmHistoryLogObject",
"alarmHistoryLogSeverity",
"alarmHistoryLogServiceAffect",
"alarmHistoryLogAddInfo",
"alarmHistoryLogOccurTime",
"alarmHistoryLogReleaseTime"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This trap will be generated when system fault is detected or released. ie. unit-out, tca, etc."
],
null
]
}Vendor MIB copy from the LibreNMS archive. FS.COM support.
Module: FS-SWITCH-V2-MIB
aAlarmEventNotify NOTIFICATION-TYPE
OBJECTS {
alarmHistoryLogSeq,
alarmHistoryLogType,
alarmHistoryLogObject,
alarmHistoryLogSeverity,
alarmHistoryLogServiceAffect,
alarmHistoryLogAddInfo,
alarmHistoryLogOccurTime,
alarmHistoryLogReleaseTime
}
STATUS current
DESCRIPTION
"This trap will be generated when system fault is detected or released.
ie. unit-out, tca, etc."
::= {alarmTrap 1}{'IF-MIB': ['ifIndex', 'InterfaceIndex', 'InterfaceIndexOrZero', 'ifIndex'], 'RMON-MIB': ['OwnerString'], 'VRRP-MIB': ['VrId'], 'SNMPv2-TC': ['TestAndIncr', 'TimeStamp', 'AutonomousType', 'DisplayString', 'PhysAddress', 'TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'MacAddress', 'RowStatus'], 'SNMPv2-SMI': ['TimeTicks', 'Counter32', 'OBJECT-IDENTITY', 'mib-2', 'MODULE-IDENTITY', 'IpAddress', 'Counter64', 'Unsigned32', 'Integer32', 'Gauge32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Downloaded: 2026-10-23T19:25:11.613118+00:00.
Vendor MIB copy from the LibreNMS archive. FS.COM support.
Module: SWITCH
aAlarmEventNotify NOTIFICATION-TYPE
OBJECTS {
alarmHistoryLogSeq,
alarmHistoryLogType,
alarmHistoryLogObject,
alarmHistoryLogSeverity,
alarmHistoryLogServiceAffect,
alarmHistoryLogAddInfo,
alarmHistoryLogOccurTime,
alarmHistoryLogReleaseTime
}
STATUS current
DESCRIPTION
"This trap will be generated when system fault is detected or released.
ie. unit-out, tca, etc."
::= {alarmTrap 1}{'IF-MIB': ['ifIndex', 'InterfaceIndex', 'InterfaceIndexOrZero', 'ifIndex'], 'RMON-MIB': ['OwnerString'], 'VRRP-MIB': ['VrId'], 'SNMPv2-TC': ['TestAndIncr', 'TimeStamp', 'AutonomousType', 'DisplayString', 'PhysAddress', 'TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'MacAddress', 'RowStatus'], 'SNMPv2-SMI': ['TimeTicks', 'Counter32', 'OBJECT-IDENTITY', 'mib-2', 'MODULE-IDENTITY', 'IpAddress', 'Counter64', 'Unsigned32', 'Integer32', 'Gauge32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Downloaded: 2026-10-23T19:25:11.701115+00:00.
Vendor MIB copy from the Observium Community archive. FS.COM support.
Module: FIBERSTORE-MIB
aAlarmEventNotify NOTIFICATION-TYPE
OBJECTS {
alarmHistoryLogSeq,
alarmHistoryLogType,
alarmHistoryLogObject,
alarmHistoryLogSeverity,
alarmHistoryLogServiceAffect,
alarmHistoryLogAddInfo,
alarmHistoryLogOccurTime,
alarmHistoryLogReleaseTime
}
STATUS current
DESCRIPTION
"This trap will be generated when system fault is detected or released.
ie. unit-out, tca, etc."
::= {alarmTrap 1}{'IF-MIB': ['ifIndex', 'InterfaceIndex', 'InterfaceIndexOrZero', 'ifIndex'], 'RMON-MIB': ['OwnerString'], 'VRRP-MIB': ['VrId'], 'SNMPv2-TC': ['TestAndIncr', 'TimeStamp', 'AutonomousType', 'DisplayString', 'PhysAddress', 'TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'MacAddress', 'RowStatus'], 'SNMPv2-SMI': ['TimeTicks', 'Counter32', 'OBJECT-IDENTITY', 'mib-2', 'MODULE-IDENTITY', 'IpAddress', 'Counter64', 'Unsigned32', 'Integer32', 'Gauge32', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressPrefixLength', 'InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages: