Reference record for OID 1.3.6.1.4.1.52642.10.5.1.2.2.1.10

Parent
1.3.6.1.4.1.52642.10.5.1.2.2.1 (fsLvEntry)
Node code
10
Node name
fsLvType
Numeric OID
1.3.6.1.4.1.52642.10.5.1.2.2.1.10
URN notation
urn:oid:1.3.6.1.4.1.52642.10.5.1.2.2.1.10
ASN.1 notation

{1 3 6 1 4 1 52642 10 5 1 2 2 1 10}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) linkAgg(10) fsLogicVolume(5) fsLvMibObjects(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) linkAgg(10) fsLogicVolume(5) onuVirPortConfigTable(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) linkAgg(10) nmsGponVirPortObj(5) fsLvMibObjects(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) linkAgg(10) nmsGponVirPortObj(5) onuVirPortConfigTable(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) nmsGponMIB(10) fsLogicVolume(5) fsLvMibObjects(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) nmsGponMIB(10) fsLogicVolume(5) onuVirPortConfigTable(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) nmsGponMIB(10) nmsGponVirPortObj(5) fsLvMibObjects(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) nmsGponMIB(10) nmsGponVirPortObj(5) onuVirPortConfigTable(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) fsStorageRef(10) fsLogicVolume(5) fsLvMibObjects(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) fsStorageRef(10) fsLogicVolume(5) onuVirPortConfigTable(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) fsStorageRef(10) nmsGponVirPortObj(5) fsLvMibObjects(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) fsStorageRef(10) nmsGponVirPortObj(5) onuVirPortConfigTable(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) mnt(10) fsLogicVolume(5) fsLvMibObjects(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) mnt(10) fsLogicVolume(5) onuVirPortConfigTable(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) mnt(10) nmsGponVirPortObj(5) fsLvMibObjects(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) fs(52642) mnt(10) nmsGponVirPortObj(5) onuVirPortConfigTable(1) fsLogicVolumeResource(2) fsLvTable(2) fsLvEntry(1) fsLvType(10)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/52642/10/5/1/2/2/1/10
  • /ISO/Identified-Organization/6/1/4/1/52642/10/5/1/2/2/1/10
  • /ISO/3/6/1/4/1/52642/10/5/1/2/2/1/10
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/fs/linkAgg/fsLogicVolume/fsLvMibObjects/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/linkAgg/fsLogicVolume/onuVirPortConfigTable/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/linkAgg/nmsGponVirPortObj/fsLvMibObjects/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/linkAgg/nmsGponVirPortObj/onuVirPortConfigTable/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/nmsGponMIB/fsLogicVolume/fsLvMibObjects/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/nmsGponMIB/fsLogicVolume/onuVirPortConfigTable/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/nmsGponMIB/nmsGponVirPortObj/fsLvMibObjects/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/nmsGponMIB/nmsGponVirPortObj/onuVirPortConfigTable/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/fsStorageRef/fsLogicVolume/fsLvMibObjects/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/fsStorageRef/fsLogicVolume/onuVirPortConfigTable/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/fsStorageRef/nmsGponVirPortObj/fsLvMibObjects/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/fsStorageRef/nmsGponVirPortObj/onuVirPortConfigTable/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/mnt/fsLogicVolume/fsLvMibObjects/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/mnt/fsLogicVolume/onuVirPortConfigTable/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/mnt/nmsGponVirPortObj/fsLvMibObjects/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • /iso/identified-organization/dod/internet/private/enterprise/fs/mnt/nmsGponVirPortObj/onuVirPortConfigTable/fsLogicVolumeResource/fsLvTable/fsLvEntry/fsLvType
  • Additional combinations skipped.

Descriptions

fsLvType — FS.COM official Documentation Hub native MIB packages

This object describes the type of a logic volume. The value 'virtual' means virtual devices are defined as sets of storage blocks from one or more physical array. This allows the creation of virtual devices that can be a portion of a larger physical array, or an aggregation of multiple physical array. The value 'direct' means direct devices are directly mapped SCSI devices. Because they are not virtualized, direct devices cannot take advantage of advanced storage options, such as mirroring, failover, replication, or snapshot copy. The value 'serviceEnabled' means service enabled devices are all maintained in a one-to-one mapping relationship(one physical array equals one logical device).

Source records

fsLvType

Status in source: current.

Names: fsLvType

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "fsLvType",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "virtual",
    "(",
    "1",
    ")",
    ",",
    "direct",
    "(",
    "2",
    ")",
    ",",
    "serviceEnabled",
    "(",
    "3",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This object describes the type of a logic volume. The value 'virtual' means virtual devices are defined as sets of storage blocks from one or more physical array. This allows the creation of virtual devices that can be a portion of a larger physical array, or an aggregation of multiple physical array. The value 'direct' means direct devices are directly mapped SCSI devices. Because they are not virtualized, direct devices cannot take advantage of advanced storage options, such as mirroring, failover, replication, or snapshot copy. The value 'serviceEnabled' means service enabled devices are all maintained in a one-to-one mapping relationship(one physical array equals one logical device).\"",
    "::=",
    "{",
    "fsLvEntry",
    "10",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "virtual",
            1
          ],
          [
            "direct",
            2
          ],
          [
            "serviceEnabled",
            3
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This object describes the type of a logic volume. The value 'virtual' means virtual devices are defined as sets of storage blocks from one or more physical array. This allows the creation of virtual devices that can be a portion of a larger physical array, or an aggregation of multiple physical array. The value 'direct' means direct devices are directly mapped SCSI devices. Because they are not virtualized, direct devices cannot take advantage of advanced storage options, such as mirroring, failover, replication, or snapshot copy. The value 'serviceEnabled' means service enabled devices are all maintained in a one-to-one mapping relationship(one physical array equals one logical device)."
    ],
    null,
    null,
    null,
    null
  ]
}
  • FS.COM official Documentation Hub native MIB packages · Publisher's source file: Source package: ies3220-8t4f-switch-snmp-mib-files.zip

    Module: FS-LOGIC-VOLUME-MIB

    Published definition
    fsLvType OBJECT-TYPE
        SYNTAX      INTEGER
            {
                virtual(1),
                direct(2),
                serviceEnabled(3)
            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object describes the type of a logic volume.
             The value 'virtual' means virtual devices are defined as sets of storage blocks
             from one or more physical array. This allows the creation of virtual devices that
             can be a portion of a larger physical array, or an aggregation of multiple physical array.
             The value 'direct' means direct devices are directly mapped SCSI devices.
             Because they are not virtualized, direct devices cannot take advantage of advanced storage options,
             such as mirroring, failover, replication, or snapshot copy.
             The value 'serviceEnabled' means service enabled devices are all maintained in a one-to-one
             mapping relationship(one physical array equals one logical device)."
        ::= { fsLvEntry 10 }
    Module imports
    {'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TEXTUAL-CONVENTION', 'TruthValue'], 'ENTITY-MIB': ['entPhysicalIndex'], 'SNMPv2-SMI': ['Counter32', 'Integer32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'FS-STORAGE-REF-MIB': ['FsLvIDType', 'FsStorageEnableState', 'FsStorageActionType', 'FsStorageLedStateType', 'FsSessionIDType', 'FsRaidIDType', 'FsWwpnListType', 'fsStorageRef']}

    Related source files and packages:

    • IES5120-28TF Switch SNMP MIB FilesIES5120-28TF Switch SNMP MIB Files; Models: IES5120-28TF; Catalog updated: 2026-02-27 15:56:52; File: mall/resource/ies5120-28tf-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:14:36 GMT; 2.6 MiB
    • IES3220-8T4F Switch SNMP MIB FilesIES3220-8T4F Switch SNMP MIB Files; Models: IES3220-8T4F; Catalog updated: 2025-12-03 14:28:43; File: mall/resource/ies3220-8t4f-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:08:16 GMT; 2.6 MiB
    • IES5120-48T4S Switch SNMP MIB FilesIES5120-48T4S Switch SNMP MIB Files; Models: IES5120-48T4S; Catalog updated: 2026-02-27 16:10:26; File: mall/resource/ies5120-48t4s-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:16:11 GMT; 2.6 MiB
    Show all 10 related files and packages
    • TSN3220-10S Switch SNMP MIB FilesTSN3220-10S Switch SNMP MIB Files; Models: TSN3220-10S; Catalog updated: 2026-01-08 09:53:00; File: mall/resource/tsn3220-10s-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:10:41 GMT; 2.6 MiB
    • IES5120-28TS-P Switch SNMP MIB FilesIES5120-28TS-P Switch SNMP MIB Files; Models: IES5120-28TS-P; Catalog updated: 2026-02-27 16:09:52; File: mall/resource/ies5120-28ts-p-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:15:40 GMT; 2.6 MiB
    • IES5220-30TS-3ES Switch SNMP MIB FilesIES5220-30TS-3ES Switch SNMP MIB Files; Models: IES5220-30TS-3ES; Catalog updated: 2025-08-19 16:17:18; File: mall/resource/ies5220-30ts-3es-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:17:18 GMT; 2.6 MiB
    • IES5220-6S-3ES Switch SNMP MIB FilesIES5220-6S-3ES Switch SNMP MIB Files; Models: IES5220-6S-3ES; Catalog updated: 2026-02-27 16:11:15; File: mall/resource/ies5220-6s-3es-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:32:47 GMT; 2.6 MiB
    • IES3220-8T4F-U Switch SNMP MIB FilesIES3220-8T4F-U Switch SNMP MIB Files; Models: IES3220-8T4F-U; Catalog updated: 2025-12-03 14:47:49; File: mall/resource/ies3220-8t4f-u-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:09:07 GMT; 2.6 MiB
    • IES5120-28TS Switch SNMP MIB FilesIES5120-28TS Switch SNMP MIB Files; Models: IES5120-28TS; Catalog updated: 2026-02-27 15:57:39; File: mall/resource/ies5120-28ts-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:15:08 GMT; 2.6 MiB
    • TSN3220-10S-U Switch SNMP MIB FilesTSN3220-10S-U Switch SNMP MIB Files; Models: TSN3220-10S-U; Catalog updated: 2025-12-16 18:11:48; File: mall/resource/tsn3220-10s-u-switch-snmp-mib-files.zip; Publisher Last-Modified: Tue, 19 Aug 2025 08:13:57 GMT; 2.6 MiB

    Source location: FS-LOGIC-VOLUME-MIB::fsLvType.
    Source version and references

    Same file in tsn3220-10s-u-switch-snmp-mib-files.zip.

    Same file in tsn3220-10s-switch-snmp-mib-files.zip.

    Same file in ies5220-6s-3es-switch-snmp-mib-files.zip.

    Same file in ies5220-30ts-3es-switch-snmp-mib-files.zip.

    Downloaded: 2026-10-24T13:35:15.526923+00:00.

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.52642)

FS.COM INC

Siblings (11)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.52642.10.5.1.2.2.1.1 fsLvIndex00
1.3.6.1.4.1.52642.10.5.1.2.2.1.2 fsLvName00
1.3.6.1.4.1.52642.10.5.1.2.2.1.3 fsLvTotalSize00
1.3.6.1.4.1.52642.10.5.1.2.2.1.4 fsLvCreateRaidUuid00
1.3.6.1.4.1.52642.10.5.1.2.2.1.5 fsLvCreateRaidSize00
1.3.6.1.4.1.52642.10.5.1.2.2.1.6 fsLvSedInquiryStringKeep00
1.3.6.1.4.1.52642.10.5.1.2.2.1.7 fsLvSedRaidUuid00
1.3.6.1.4.1.52642.10.5.1.2.2.1.8 fsLvState00
1.3.6.1.4.1.52642.10.5.1.2.2.1.9 fsLvAssigned00
1.3.6.1.4.1.52642.10.5.1.2.2.1.11 fsLvExtendTimes00
1.3.6.1.4.1.52642.10.5.1.2.2.1.12 fsLvRowStatus00