Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"switchRenumberUnitID",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"renumber",
"(",
"1",
")",
",",
"noRenumber",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value renumber will automatically assign an ID to units in the stack; all UNIT IDs will be contiguous. The system configurations are not changed but the system will restart after renumbering is completed.\"",
"::=",
"{",
"switchMgt",
"14",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"renumber",
1
],
[
"noRenumber",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value renumber will automatically assign an ID to units in the stack; all UNIT IDs will be contiguous. The system configurations are not changed but the system will restart after renumbering is completed."
],
null,
null,
null,
null
]
}