Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fsIfMonThresholdTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"FsIfMonThresholdEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This table is about the upper threshold, lower threshold, CRC type, and inspection interval. The upper threshold and lower threshold must be bound together. If the CRC type is configured, node fsIfMonCRCErrType must be carried. If there is no current configuration for a type, all attributes of this type must be carried. After modification, the table fsIfMonAlarmDownEnableTable will be changed.If there is configuration for the current type, setting all attributes of this type to invalid values indicates that the configuration of this type is deleted, and the table fsIfMonAlarmDownEnableTable will be changed. Take CRC as an example. If there is no CRC configuration, nodes fsIfMonCRCErrorLowThres, fsIfMonCRCErrorLowThres, fsIfMonCRCErrorLowThres, and fsIfMonCRCErrorLowThres must be carried. After modification, the node fsIfMonCRCErrorEnableDown becomes false. If there is CRC configuration, settings the nodes fsIfMonCRCErrorLowThres, fsIfMonCRCErrorHighThres, fsIfMonCRCErrorInterval, and fsIfMonCRCErrorInterval to invalid values indicates the CRC configuration is deleted, and the node fsIfMonCRCErrorEnableDown becomes invalid.\"",
"::=",
"{",
"fsIfMonControl",
"1",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"FsIfMonThresholdEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This table is about the upper threshold, lower threshold, CRC type, and inspection interval. The upper threshold and lower threshold must be bound together. If the CRC type is configured, node fsIfMonCRCErrType must be carried. If there is no current configuration for a type, all attributes of this type must be carried. After modification, the table fsIfMonAlarmDownEnableTable will be changed.If there is configuration for the current type, setting all attributes of this type to invalid values indicates that the configuration of this type is deleted, and the table fsIfMonAlarmDownEnableTable will be changed. Take CRC as an example. If there is no CRC configuration, nodes fsIfMonCRCErrorLowThres, fsIfMonCRCErrorLowThres, fsIfMonCRCErrorLowThres, and fsIfMonCRCErrorLowThres must be carried. After modification, the node fsIfMonCRCErrorEnableDown becomes false. If there is CRC configuration, settings the nodes fsIfMonCRCErrorLowThres, fsIfMonCRCErrorHighThres, fsIfMonCRCErrorInterval, and fsIfMonCRCErrorInterval to invalid values indicates the CRC configuration is deleted, and the node fsIfMonCRCErrorEnableDown becomes invalid."
],
null,
null,
null,
null
]
}